AD/A119/5 - Windshield Wipers
Airworthiness Directive - AD/A119/5 - Windshield Wipers
Airworthiness Directive - AD/A119/5 - Windshield Wipers CASA Airworthiness Directive Jurisdiction:Commonwealth of Australia;CorporateName:Civil Aviation Safety Authority; Issue 8/2002,Rotorcraft,Agusta A119 Series Helicopters,Windshield Wipers,5 DellaCa, Donna 2 1 2022-10-25T23:59:00Z 2022-10-26T00:00:00Z 2 421 2403 Office of Parliamentary Counsel 20 5 2819 16.0000
2006-09-22T00:00:00Z Toolkit http://www.activepdf.com 2022-10-25T00:00:00Z
AIRWORTHINESS
DIRECTIVE
For the
reasons set
out in
the background
section, the
CASA delegate
whose signature
appears below
issues the
following Airworthiness
Directive (AD)
under
subregulation
39.1
(1)
of
CAR
1998.
The
AD
requires
that
the
action
set
out
in
the
requirement
section
(being
action
that
the
delegate
considers
necessary
to
correct
the
unsafe
condition)
be
taken
in
relation
to
the
aircraft
or
aeronautical
product
mentioned
in
the
applicability
section:
(a)
in
the
circumstances
mentioned
in
the
requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
Agusta
A119
Series
Helicopters
AD/A119/5 Windshield Wipers 8/2002
TX
Applicability: A119
helicopters
all
serial
numbers
(S/N)
up
to
and
including
14022.
Requirement: 1. Helicopters
S/N
14017
to
14021
inclusive
- Deactivate
the
windshield
wipers and install the following placard in accordance with Part I of Agusta Alert Bollettino Tecnico 119-5 dated 22 May 2002:
“WINDSHIELD
WIPERS
INOPERATIVE”
2.
Helicopters S/N 14017 to 14021 inclusive
- Modify the windshield wiper electrical
system
in
accordance
with
Part
II
of
Alert
Bollettino
Tecnico
119-5.
3.
Helicopters
S/N
up
to
and
including
14022,
but excluding
S/N
14017,
14018, 14019, 14020 and 14021
- Modify the windshield wiper electrical system in accordance with Part III of Alert Bollettino Tecnico 119-5.
Note:
Italian
Ente
Nazionale
per
l’Aviazone
Civile
AD
2002-309
refers.
Compliance: For
Requirement
1
- Within
five
hours ’
time
in
service
after
the
effective
date
of
this
Directive.
For
Requirement
2
-
Before
31
October
2002.
For
Requirement
3
- When
relay
part
number
(P/N)
T412-DJ1001-C
is
replaced
with relay P/N TDH-8070-1001P and/or T412-2006.
This
Airworthiness
Directive
becomes
effective
on
21
June
2002.
Background: Agusta has advised that during a ground functional test of an A109E helicopter the windshield wiper electrical system overheated due to a system overload.
The source of the overload was identified as a partial incompatibility of new timed relays P/N TDH-8070-1001P
and/or
T412-2006
(identified
as
K8651
and
K8652)
with
the
actual configuration of the windshield wiper electrical system.
Agusta
A119
Series
Helicopters
AD/A119/5
(continued)
As
109E
and
A119
helicopters
are
equipped
with
the
same
windshield
wiper
electrical system overheating could also occur on A119 helicopters.
This Directive requires initial deactivation of the wiper system followed by modification of the system to eliminate the overheating.
Eugene
Paul
Holzapfel
Delegate
of
the
Civil
Aviation
Safety
Authority 19 June 2002
The
above
AD
is
notified
in
the
Commonwealth
of
Australia
Gazette
on
21
June
2002.
Official source: https://www.legislation.gov.au/Details/F2006B01845