AD/A320/124 Amdt 2 - Overwing Emergency Exit Door Frame Corners
Airworthiness Directive - AD/A320/124 Amdt 2 - Overwing Emergency Exit Door Frame Corners
Airworthiness Directive - AD/A320/124 Amdt 2 - Overwing Emergency Exit Door Frame Corners CASA Airworthiness Directive Jurisdiction:Commonwealth of Australia;CorporateName:Civil Aviation Safety Authority; Issue 11/2004,Aircraft above 5700 kg,Airbus Industrie A319, A320 and A321 Series Aeroplanes,Overwing Emergency Exit Door Frame Corners,124 Amdt 2 DellaCa, Donna 2 0 2022-10-26T02:15:00Z 2022-10-26T02:15:00Z 2 436 2489 Office of Parliamentary Counsel 20 5 2920 16.0000
2006-09-22T00:00:00Z Toolkit http://www.activepdf.com 2022-10-26T00:00:00Z
AIRWORTHINESS
DIRECTIVE
For the reasons set out in the background section, the CASA
delegate
whose
signature
appears
below
revokes
Airworthiness
Directive
(AD)
AD/A320/124
Amdt 1 and issues the
following
AD
under subregulation 39.1 (1) of CASR 1998. The
AD
requires that the
action set out in the
requirement section (being
action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the
applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement
section; and (c) at the time mentioned in the compliance section.
Airbus
Industrie
A319,
A320
and
A321
Series
Aeroplanes
AD/A320/124
Amdt
2
Overwing
Emergency
Exit Door
Frame
Corners 11/2004
Applicability: Model
A320-200
aircraft,
serial
numbers
MSN
0624
through
MSN
1141. Model A319 aircraft, all serial numbers up to and including MSN 1167.
Requirement: 1. Perform a detailed visual inspection of affected rivets to detect loose and/or missing
rivets
in
accordance
with
Airbus
Service
Bulletin
A320-53-1147
original issue, Revision 01, or Revision 02.
2. Remove all the affected rivets in all specified corner areas and check the interior countersinks
in
accordance
with
Airbus
Service
Bulletin
A320-53-1147
Revision
02.
Note
1:
Accomplishment
of
Requirement
2
constitutes
terminating
action
for
the Requirement 1 inspection.
Note
2:
DGAC
AD
2003-147(B)
R1
refers.
Compliance: 1. Within
3,500
flight
cycles
after
4
October
2001.
Repeat
inspection
at
intervals
not
to
exceed
3,500
flight
cycles
in
accordance
with Revision 02 of the Requirement document; until Requirement 2 is accomplished.
2. Before the accumulation of 24,000 flight cycles. The
compliance
times
remain
unchanged
by
this
issue.
This
Amendment
becomes
effective
on
28
October
2004.
Background: A
report
was
received
of
a
loose
ABS213
rivet
at
the
overwing
emergency
exit
door frame corners of A320 and A319 aircraft.
Further investigation revealed several instances where the grip length of the rivets was slightly out of tolerance.
This condition could affect the structural integrity
of the overwing
exit frame in the long
term.
Amendment 1 introduced a supplemental inspection program to verify/measure affected
rivet
hole
interior
countersinks,
and
clarified
Requirement
1
compliance.
Airbus
Industrie
A319,
A320
and
A321
Series
Aeroplanes
AD/A320/124
Amdt
2
(continued)
Amendment
2
is
issued
to
introduce
AD
2003-147(B)
R1
to
Requirement
Note
2
as the related DGAC AD.
The
original
issue
of
this
Airworthiness
Directive
became
effective
on
4
October
2001.
David
Villiers
Delegate
of
the
Civil
Aviation
Safety
Authority 16 September 2004
The
above
AD
is
notified in the
Commonwealth
of Australia Gazette
on 6 October
2004.
Official source: https://www.legislation.gov.au/Details/F2006B01871