AD/A320/152 - Auxiliary Power Unit Alternating Current Generator
Airworthiness Directive - AD/A320/152 - Auxiliary Power Unit Alternating Current Generator
Airworthiness Directive - AD/A320/152 - Auxiliary Power Unit Alternating Current Generator CASA Airworthiness Directive Jurisdiction:Commonwealth of Australia;CorporateName:Civil Aviation Safety Authority; Issue 4/2004,Aircraft above 5700 kg,Airbus Industrie A319, A320 and A321 Series Aeroplanes,Auxiliary Power Unit Alternating Current Generator,152 DellaCa, Donna 2 0 2022-10-26T21:20:00Z 2022-10-26T21:21:00Z 2 416 2376 Office of Parliamentary Counsel 19 5 2787 16.0000
2006-09-22T00:00:00Z Toolkit http://www.activepdf.com 2022-10-26T00:00:00Z
AIRWORTHINESS
DIRECTIVE
For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD)
under subregulation 39.1 (1) of CASR 1998.
The AD requires that the action set out in the requirement section (being action that the delegate considers
necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the
circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time
mentioned in the compliance section.
Airbus
Industrie
A319,
A320
and
A321
Series
Aeroplanes
AD/A320/152 Auxiliary
Power
Unit
Alternating
Current
Generator
4/2004
Applicability: A319,
A320
and
A321
series
aeroplanes,
all
serial
numbers,
equipped
with
Hamilton Sundstrand Auxiliary Power Unit (APU) alternating current (AC) generator part number (P/N) 5906732, 5909006 or 5910047 with modification up to 17
incorporated.
Note 1:
Documentation from both Airbus and the French Direction Générale de l’Aviation
Civile
refer
to
the
AC
generators
having
amendments
up
to
17
rather
than
modifications.
Note
2:
No
action
is
required
by
this
Airworthiness
Directive
for
aircraft
that
have embodied Airbus Modification 32614 during production or incorporated Airbus Industrie Service Bulletin (SB) A320-24-1106 whilst in service, provided that no generator has been replaced since the modification or SB was incorporated.
Requirement: Unless
already
accomplished,
replace
all
four
bolts
that
retain
the
electrical
receptacle of the APU AC generator with bolts P/N 5910191-30 and lock wire the bolts in accordance with the instruction given in SB A320-24-1106 (Hamilton Sundstrand Goodrich Power Systems SB 90EGS01AG-24-18 is also applicable).
Note
3:
DGAC
AD
F-2004-019
refers.
Compliance: Before
30
October
2005.
This
Airworthiness
Directive
becomes
effective
on
15
April
2004.
Airbus
Industrie
A319,
A320
and
A321
Series
Aeroplanes
AD/A320/152
(continued)
Background: The DGAC has advised that an operator reported a blast in the APU compartment, that
blew
open
the
APU
compartment
doors,
damaging
aircraft’s
tail
cone
structure and the left elevator surface.
Analysis revealed, that vibrations in APU AC generators loosened the electrical receptacle retaining bolts, which lead to oil vapor leakage.
This leakage, associated with
an
electrical
arc
at
the
electrical
receptacle,
was
determined
to
be
the
cause
of
the
blast.
James
Coyne
Delegate
of
the
Civil
Aviation
Safety
Authority 4 March 2004
The
above
AD
is
notified
in
the
Commonwealth
of
Australia
Gazette
on
24
March
2004.
Official source: https://www.legislation.gov.au/Details/F2006B01897