Victorian Energy Efficiency Target Regulations 2008
i
Victorian Energy Efficiency Target Regulations
2008
S.R. No. 158/2008
TABLE OF PROVISIONS
Regulation Page
PART 1—PRELIMINARY 1
1 Objectives 1
2 Authorising provisions 2
3 Commencement 2
4 Definitions 2
5 Standards 5
PART 2—PRESCRIBED ACTIVITIES 6
6 Prescribed activities for which certificates may be created 6
7 Time at which prescribed activity is undertaken 9
8 Certificate not to be created more than once for same product
or activity 10
9 Register to be kept by the ESC 10
10 Conditions and circumstances under which a certificate cannot
be created 11
PART 3—GENERAL 12
11 Shortfall penalty rate 12
12 Scheme acquisition 13
__________________
SCHEDULES 14
SCHEDULE 1—Water Heater 14
PART A—CRITERIA 14
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 15
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 17
-- 1 of 106 --
Regulation Page
ii
SCHEDULE 2—Solar Retrofit Kit 19
PART A—CRITERIA 19
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 19
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 20
SCHEDULE 3—Solar Water Heater 21
PART A—CRITERIA 21
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 21
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 22
SCHEDULE 4—Solar Pre—Heater 23
PART A—CRITERIA 23
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 23
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 24
SCHEDULE 5—High Efficiency Ducted Gas Heater Replacing a
Ducted Gas Heater 25
PART A—CRITERIA 25
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 25
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 27
SCHEDULE 6—High Efficiency Ducted Gas Heater Replacing a
Central Electric Resistance Heater 28
PART A—CRITERIA 28
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 28
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 30
-- 2 of 106 --
Regulation Page
iii
SCHEDULE 7—High Efficiency Ducted Air to Air Heat Pump
Replacing a Ducted Air to Air Heat Pump 31
PART A—CRITERIA 31
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 31
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 33
SCHEDULE 8—High Efficiency Ducted Air to Air Heat Pump
Replacing Central Electric Resistance Heater 34
PART A—CRITERIA 34
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 34
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 36
SCHEDULE 9—Gas or Liquefied Petroleum Gas Space Heater 37
PART A—CRITERIA 37
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 37
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 39
SCHEDULE 10—Space Air to Air Heat Pump 40
PART A—CRITERIA 40
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 40
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 43
SCHEDULE 11—Ceiling Insulation 44
PART A—CRITERIA 44
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 44
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 45
SCHEDULE 12—Under Floor Insulation 46
PART A—CRITERIA 46
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 46
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 47
-- 3 of 106 --
Regulation Page
iv
SCHEDULE 13—Thermally Efficient Window 48
PART A—CRITERIA 48
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 48
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 49
SCHEDULE 14—Installation of Product on Single Glazed Window
Raising Thermal Efficiency 50
PART A—CRITERIA 50
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 50
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 51
SCHEDULE 15—Weather Sealing 52
PART A—CRITERIA 52
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 53
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 54
SCHEDULE 16—Lighting 55
PART A—CRITERIA 55
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 56
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 62
SCHEDULE 17—Low Flow Shower Rose 63
PART A—CRITERIA 63
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 63
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 64
SCHEDULE 18—High Efficiency Refrigerators and Freezers 65
PART A—CRITERIA 65
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 66
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 67
-- 4 of 106 --
Regulation Page
v
SCHEDULE 19—Destruction of Pre-1996 Refrigerator or
Freezer 68
PART A—CRITERIA 68
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES 68
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN 69
SCHEDULE 20—Data Table 70
═══════════════
ENDNOTES 96
-- 5 of 106 --
1
STATUTORY RULES 2008
S.R. No. 158/2008
Victorian Energy Efficiency Target Act 2007
Victorian Energy Efficiency Target Regulations
2008
The Governor in Council makes the following Regulations:
Dated: 11 December 2008
Responsible Minister:
PETER BATCHELOR
Minister for Energy and Resources
RYAN HEATH
Clerk of the Executive Council
PART 1—PRELIMINARY
1 Objectives
The objectives of these Regulations are to
prescribe—
(a) activities carried out in residential premises
that result in reduction of greenhouse gas
emissions that would not otherwise have
occurred if the activities were not
undertaken;
(b) the shortfall penalty rate;
(c) the method and variables to calculate in
tonnes the carbon dioxide equivalent of
greenhouse gases to be reduced by a
prescribed activity;
-- 6 of 106 --
Part 1—Preliminary
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
2
(d) any other matter or thing authorised or
required to be prescribed or necessary to be
prescribed for carrying the Act into effect.
2 Authorising provisions
These Regulations are made under section 75 of
the Victorian Energy Efficiency Target Act
2007.
3 Commencement
These Regulations come into operation on
1 January 2009.
4 Definitions
In these Regulations—
Act means the Victorian Energy Efficiency
Target Act 2007;
accredited body, in relation to a product, means a
body accredited under the Joint
Accreditation System of Australia and New
Zealand to give product certification or
component certification of a product;
B e means the annual electrical energy used by
those parts of a solar or heat pump water
heater system that use purchased electrical
energy, other than resistive heating units or
heat pump package (compressor and integral
controls, pumps and fans) (MJ/Yr)
determined as part of the performance
evaluation process in AS 4234—1994;
B s means the annual supplementary purchased gas
or electrical energy used by a solar or heat
pump water heater to directly heat the water
by a gas burner, electrical resistive heating
unit and/or heat pump package (compressor
and integral controls, pumps and fans)
(MJ/Yr) determined as part of the
r. 2
-- 7 of 106 --
Part 1—Preliminary
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
3
performance evaluation process in
AS 4234—1994;
Building Code means the Building Code of
Australia within the meaning of section 3(1)
of the Building Act 1993;
climatic region, in relation to a geographic area
identified by a postcode in column 2 of an
item in the Data Table (or, if that area is no
longer identified by such a postcode, the
postcode in column 2 of an item in the Data
Table by which it was last identified), means
the climatic region specified in column 5 of
that item;
coefficent of performance, in relation to a
product, means the ratio of its rated heating
capacity to its effective power input at its
rated heating capacity;
decommission means disable and render
permanently unusable;
Data Table means the Table in Schedule 20;
ESC register means the register kept by the ESC
under regulation 9;
glazing has the same meaning as in Part 2.6 of the
Building Code;
install—
(a) includes modify or replace; and
(b) in relation to a prescribed activity
specified in regulation 6(r), means the
purchase of a high efficiency
refrigerator or high efficiency freezer
evidenced by a written record of the
purchase that includes the name and
address of the purchaser;
r. 4
-- 8 of 106 --
Part 1—Preliminary
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
4
lighting source efficacy means the initial
luminous flux of a lamp or the total radiant
flux in the visible spectrum weighted by the
spectral response of the eye, divided by the
electric power that will be consumed by the
lamp but excluding ballast and control gear
power losses;
metropolitan Victoria means a geographical area
identified by a postcode in column 2 of an
item in the Data Table (or, if that area is no
longer identified by such a postcode, the
postcode in column 2 of an item in the Data
Table by which it was last identified) and
specified in column 3 of that item as
Metropolitan;
MEPS means minimum energy performance
standard;
non-gas reticulated area means a geographical
area identified by a postcode in column 2 of
an item in the Data Table (or, if that area is
no longer identified by such a postcode, the
postcode in column 2 of an item in the Data
Table by which it was last identified) and
specified in column 4 of that item as an area
to which gas is not reticulated;
product includes appliance, equipment and
material;
R-value means the thermal resistance (m2 K/W) of
a component calculated by dividing its
thickness by its thermal conductivity;
regional Victoria means a geographical area
identified by a postcode in column 2 of an
item in the Data Table (or, if that area is no
longer identified by such a postcode, the
postcode by which it was last identified) and
r. 4
-- 9 of 106 --
Part 1—Preliminary
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
5
specified in column 3 of that item as
Regional;
residential customer, in relation to a relevant
entity, means a person who purchases
electricity or gas principally for personal,
household or domestic use;
residential premises means a building classified
under Part A3 of the Building Code as a
Class 1, 2, 3 or 4 building;
Total U-Value means the thermal transmittance
(W/m 2 K) of the composite element allowing
for the effect of any airspace and associated
surface resistances;
WERS means the Window Energy Rating Scheme
managed by the Australian Window
Association;
window includes glass roof light, glass panel,
glass block, glass brick, glazed sash, glazed
part of a door or similar glass product that,
when closed, transmits natural light from
outside residential premises to the inside but
does not include a louvred product.
5 Standards
In these Regulations, unless the contrary intention
appears, a reference to a standard is a reference to
that standard as in force at the time these
Regulations are made.
__________________
r. 5
-- 10 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
6
PART 2—PRESCRIBED ACTIVITIES
6 Prescribed activities for which certificates may be
created
The following activities undertaken in residential
premises are prescribed for the purposes of
section 15 of the Act—
(a) decommissioning an electric resistance water
heater and installing a product that complies
with the criteria specified in Part A of
Schedule 1;
(b) installing on an electric resistance water
heater a product that complies with the
criteria specified in Part A of Schedule 2;
(c) decommissioning a gas or liquefied
petroleum gas water heater and installing a
product that complies with the criteria
specified in Part A of Schedule 3;
(d) installing on a gas or liquefied petroleum gas
water heater a solar pre-heater that complies
with the criteria specified in Part A of
Schedule 4;
(e) decommissioning a ducted gas space heater
and installing a product that complies with
the criteria specified in Part A of Schedule 5;
(f) decommissioning a central electric resistance
heater that provides heating to a space with a
floor area of at least 100m2 and installing a
product that complies with the criteria
specified in Part A of Schedule 6;
(g) if the residential premises are in a non-gas
reticulated area, decommissioning a ducted
air to air heat pump and installing a product
that complies with the criteria specified in
Part A of Schedule 7;
r. 6
-- 11 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
7
(h) if the residential premises are in a non-gas
reticulated area, decommissioning a central
electric resistance heater that provides
heating to a space with a floor area of at least
100m 2 and installing a product that complies
with the criteria specified in Part A of
Schedule 8;
(i) installing a gas or liquefied petroleum gas
space heater that is flued and complies with
the criteria specified in Part A of Schedule 9;
(j) if the residential premises are in a non-gas
reticulated area, installing a space air to air
heat pump that complies with the criteria
specified in Part A of Schedule 10;
(k) installing a product in accordance with
AS 3999—1992 in a ceiling area not
previously insulated for a minimum area of
20m 2 , being a product that complies with the
criteria specified in Part A of Schedule 11;
(l) installing a product as under floor insulation
in accordance with AS 3999—1992 in
respect of a floor area not previously
insulated for a minimum area of 20m 2 , being
a product that complies with the criteria
specified in Part A of Schedule 12;
(m) installing, in place of one or more windows
in an external wall, at least 5m 2 of glazing or
glazed product that complies with the criteria
specified in Part A of Schedule 13;
(n) installing on one or more single glazed
windows in an external wall for a minimum
glazing area of 5m 2 , a product that complies
with the criteria specified in Part A of
Schedule 14;
r. 6
-- 12 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
8
(o) in the same residential premises, undertaking
any one or more of the following activities to
restrict the airflow into or out of the premises
(not being an activity, or two or more
activities that together, result in the premises
failing to receive natural air changes at a rate
of at least 0⋅5 per hour or to comply with the
minimum ventilation requirements of
Part 3.8.5 of the Building Code)—
(i) installing a product that complies with
the criteria specified in item 15A in
Part A of Schedule 15 to the frame of,
or each edge of, an external door or to
the frame and each edge of an external
door;
(ii) installing a product that complies with
the criteria specified in item 15B in
Part A of Schedule 15 to the frame of
an external window;
(iii) removing a ceiling or wall exhaust fan
and decommissioning it and installing a
ceiling or wall exhaust fan that
complies with the criteria specified in
item 15C in Part A of Schedule 15;
(iv) installing on an exhaust fan a product
that complies with the criteria in
item 15D in Part A of Schedule 15;
(v) permanently sealing or closing
ventilation openings in an external wall
with material that complies with the
criteria specified in item 15E in Part A
of Schedule 15;
r. 6
-- 13 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
9
(vi) installing a product that complies with
the criteria specified in item 15F in
Part A of Schedule 15 to a chimney or
flue of an open solid fuel burning
appliance;
(p) installing lamps that comply with the criteria
specified in Part A of Schedule 16 and,
where installed in place of lamps that do not
comply with those criteria, decommissioning
those lamps;
(q) decommissioning a non-low flow shower
rose (not being a shower rose rated as having
a 3 star or higher water efficiency when
assessed and labelled in accordance with
AS/NZS 6400:2005) and installing a low
flow shower rose that complies with the
criteria specified in Part A of Schedule 17;
(r) installing a high efficiency refrigerator or
high efficiency freezer that complies with the
criteria specified in Part A of Schedule 18;
(s) removing from the residential premises a
refrigerator or freezer manufactured before
1996 and in working order and destroying
the refrigerator or freezer in accordance with
the criteria specified in Part A of
Schedule 19.
7 Time at which prescribed activity is undertaken
For the purposes of section 17(2) of the Act, a
prescribed activity referred to in regulation 6 is to
be taken to have been undertaken at the time
specified in Part C of the Schedule applying to
that prescribed activity.
r. 7
-- 14 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
10
8 Certificate not to be created more than once for
same product or activity
(1) Except as provided in subregulation (2), if a
certificate has been created for a prescribed
activity involving the installation of a product
(other than lamps or shower roses) in residential
premises, a certificate must not be issued in
respect of—
(a) any other prescribed activity involving that
product; or
(b) any prescribed activity of the same class as
the first mentioned prescribed activity that is
undertaken in those residential premises.
(2) Subregulation (1)(b) does not apply to the
following—
(a) a prescribed activity involving the
installation of a second water heating
product referred to in Schedule 1, 2, 3 or 4;
(b) a prescribed activity involving the
installation of a second heating product
referred to in Schedule 5, 6, 7, 8, 9 or 10;
(c) a prescribed activity involving the
installation of a second refrigerator or freezer
referred to in Schedule 18.
9 Register to be kept by the ESC
(1) The ESC must establish and keep a register of
products that may be installed in residential
premises under a prescribed activity and in respect
of which a certificate may be created.
(2) The register kept under this regulation must
include the product type, brand name, model name
or number and any other relevant details sufficient
to identify each product recorded in the register.
r. 8
-- 15 of 106 --
Part 2—Prescribed Activities
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
11
(3) The ESC must cause—
(a) the register kept under this regulation to be
available for inspection at its office; and
(b) a copy of the register to be published on its
website and, so far as is practicable, kept up
to date; and
(c) a copy of the register to be published in the
Government Gazette at least once each year;
and
(d) a copy of all changes (if any) made to the
register since it was last published in the
Government Gazette to be published in the
Government Gazette at least once every
three months.
10 Conditions and circumstances under which a
certificate cannot be created
For the purposes of section 17(4) of the Act, the
following are conditions and circumstances in
which a certificate cannot be created in relation to
a prescribed activity—
(a) if the prescribed activity is an activity—
(i) undertaken in residential premises; and
(ii) that, under the Building Code, is
undertaken as a performance
requirement in relation to those
premises; or
(b) if, at the time the prescribed activity is
undertaken, the accredited person proposing
to create the certificate is a person whose
accreditation is suspended.
__________________
r. 10
-- 16 of 106 --
Part 3—General
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
12
PART 3—GENERAL
11 Shortfall penalty rate
(1) The prescribed shortfall penalty rate for the
purposes of section 28 of the Act is $40 as varied
in accordance with this regulation.
(2) The amount referred to in subregulation (1) that is
to apply in respect of 2010 and each subsequent
year is to be varied in accordance with the
formula—
C
B
A ×
where—
A is the amount referred to in
subregulation (1);
B is the all groups consumer price index for
Melbourne published by the Australian
Statistician in respect of the September
quarter of the previous year;
C is the all groups consumer price index for
Melbourne published by the Australian
Statistician in respect of the 2009 September
quarter.
(3) If an amount is varied in accordance with this
regulation, subregulation (1) has effect as if a
reference to the amount referred to in
subregulation (1) were a reference to the amount
so varied.
(4) The ESC must cause a notice to be published in
the Government Gazette specifying the amount as
varied for the purposes of subregulation (1) in
respect of the relevant year.
r. 11
-- 17 of 106 --
Part 3—General
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
13
12 Scheme acquisition
For the purpose of the definition of scheme
acquisition in section 3 of the Act, all residential
customers of gas or electricity in Victoria are
prescribed customers.
__________________
r. 12
-- 18 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
14
SCHEDULES
SCHEDULE 1
Regulation 6(a)
WATER HEATER
Prescribed activity under regulation 6(a): Decommissioning an electric
resistance water heater and installing a product that complies with the
criteria specified in Part A of Schedule 1.
PART A—CRITERIA
Item
1A Gas or liquefied petroleum gas storage water heater
certified by an accredited body as achieving a minimum
5 star rating when tested and rated in accordance with
AS 4552/AG102—2000 or AS 4552—2005 and listed in
the ESC register.
1B Gas or liquefied petroleum gas instantaneous water heater
certified by an accredited body as achieving a minimum
5 star rating when tested and rated in accordance with
AS 4552/AG102—2000 or AS 4552—2005 and listed in
the ESC register.
1C Electric boosted solar or heat pump water heater certified
by an accredited body to AS/NZS 2712:2007, achieving a
minimum energy performance of 60% solar contribution
in zone 4 (Melbourne) climate as determined in
accordance with AS 4234—1994 and listed in the ESC
register.
1D Gas or liquefied petroleum gas boosted solar water heater
certified by an accredited body to AS/NZS 2712:2007,
achieving a minimum energy performance of 60% solar
contribution in zone 4 (Melbourne) climate as determined
in accordance with AS 4234—1994 and listed in the ESC
register.
Sch. 1
-- 19 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
15
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of an electric resistance water heater, and
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor (if any) applying to the place where the
product is installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
1A Abatement factor:
(a) If the product has a storage capacity less than
95 litres: 18⋅0
(b) If the product has a storage capacity of
95 litres or more but not more than 140 litres: 32⋅8
(c) If the product has a storage capacity of more
than 140 litres: 43⋅0
1B Abatement factor:
(a) If the product has a water heating capacity
(L/min) @ 25°C rise of less than 18 L/min: 19⋅7
(b) If the product has a water heating capacity
(L/min) @ 25°C rise of 18 L/min or more
but not more than 22 L/min: 33⋅7
(c) If the product has a water heating capacity
(L/min) @ 25°C rise of more than 22 L/min: 43⋅1
Sch. 1
-- 20 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
16
1C Abatement factor:
(a) If the product is a small system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e s B B + 003938 0 47 0 4 × ⋅ − ⋅ ;
(ii) is installed in regional Victoria:
( ) [ ] e s B B + 004163 0 79 42 × ⋅ − ⋅ ;
(b) If the product is a large system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e s B B + 003938 0 2 6 65 × ⋅ − ⋅ ;
(ii) is installed in regional Victoria:
( ) [ ] e s B B + 004163 0 37 69 × ⋅ − ⋅ .
1D Abatement factor:
(a) If the product is a small system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B s B × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 015 0 47 0 4 ;
(ii) is installed in regional Victoria:
( ) [ ] e B s B × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 015 0 79 42 ;
Sch. 1
-- 21 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
17
(b) If the product is a large system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B s B × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 015 0 62 65 ;
(ii) is installed in regional Victoria:
( ) [ ] e B s B × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 015 0 37 69 .
1A–1B Regional factor:
(a) If the product is installed in metropolitan
Victoria: 0⋅97;
(b) If the product is installed in regional
Victoria: 1⋅05.
1C–1D Regional factor: 1.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
1A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver water heated by gas or liquefied petroleum
petroleum gas and the day on which the electric resistance
water heater is decommissioned.
1B At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver water heated by gas or liquefied petroleum gas and
the day on which the electric resistance water heater is
decommissioned.
1C At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver water heated by solar energy and the day on which
the electric resistance water heater is decommissioned.
Sch. 1
-- 22 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
18
1D At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver water heated by solar energy and the day on which
the electric resistance water heater is decommissioned.
__________________
Sch. 1
-- 23 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
19
SCHEDULE 2
Regulation 6(b)
SOLAR RETROFIT KIT
Prescribed activity under regulation 6(b): Installing on an electric resistance
water heater a product that complies with the criteria specified in Part A of
Schedule 2.
PART A—CRITERIA
Item
2A Solar retrofit kit (solar collector, pump and controller)
certified by an accredited body to AS/NZS 2712:2007
with a performance evaluated using the Plumbing
Characteristics specified in the Sustainability Victoria
Guidelines to calculate annual solar energy savings for
domestic solar water heaters—produced by adding a
Retrofit Kit (collectors and pump) to an existing tank
(version 5.1 updated October 2008), achieving a minimum
energy performance of 50% solar contribution in zone 4 as
determined in accordance with AS 4234—1994 and listed
in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 2
-- 24 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
20
The following are the abatement factors and regional factors for
an item in Part A:
Item
2A Abatement factor:
(a) If the product is installed in metropolitan Victoria:
( ) [ ] e B Bs + 001706 0 44 28 × ⋅ − ⋅ ;
(b) If the product is installed in regional Victoria:
( ) [ ] e B Bs + 001804 0 06 30 × ⋅ − ⋅ .
2A Regional factor: 1
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
2A At the beginning of the day on which the electric
resistance heater, as modified by the installed product, is
first able to produce and deliver water heated by solar
energy.
__________________
Sch. 2
-- 25 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
21
SCHEDULE 3
Regulation 6(c)
SOLAR WATER HEATER
Prescribed activity under regulation 6(c): Decommissioning a gas or liquefied
petroleum gas water heater and installing a product that complies with the
criteria specified in Part A of Schedule 3.
PART A—CRITERIA
Item
3A Gas or liquefied petroleum gas boosted solar water heater
certified by an accredited body to AS/NZS 2712:2007
achieving a minimum energy performance of 60% solar
contribution in zone 4 as determined in accordance with
AS 4234—1994 and listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of a gas or liquefied petroleum gas heater
and the installation of a product referred to in an item in Part A
is determined by multiplying the abatement factor for that item
by the regional factor applying to the place where the product is
installed.
Sch. 3
-- 26 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
22
The following are the abatement factors and regional factors for
each item in Part A:
Item
3A Abatement factor:
(a) If the product is a small system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 015 0 27 12 ;
(ii) is installed in regional Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 015 0 27 12 ;
(b) If the product is a large system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 015 0 95 17 ;
(ii) is installed in regional Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 015 0 95 17 ;
3A Regional factor: 1
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
3A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver water heated by solar energy and the day on which
the gas or liquefied petroleum gas water heater is
decommissioned.
__________________
Sch. 3 Sch. 3
-- 27 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
23
SCHEDULE 4
Regulation 6(d)
SOLAR PRE—HEATER
Prescribed activity under regulation 6(d): Installing on a gas or liquefied
petroleum gas water heater a solar pre-heater that complies with the criteria
specified in Part A of Schedule 4.
PART A—CRITERIA
Item
4A Solar pre-heater certified by an accredited body to
AS/NZS 2712:2007 with a performance evaluated using
the Post Heater Characteristics specified in Sustainability
Victoria's Guidelines to calculate annual solar energy
savings for domestic solar water heaters—produced by
adding a solar pre-heater to an existing gas hot water
system (Version 2.3 updated October 2008), achieving a
minimum energy performance of 50% solar contribution
in zone 4 as determined in accordance with
AS 4234—1994 and listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 4
-- 28 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
24
The following are the abatement factors and regional factors for
an item in Part A:
Item
4A Abatement factor:
(a) If the product is a small system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 006 0 53 7 ;
(ii) is installed in regional Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 006 0 53 7 ;
(b) If the product is a large system as determined in
accordance with AS 4234—1994 based on the
system's peak daily thermal energy load delivery
characteristics and—
(i) is installed in metropolitan Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2625 0 + 0573 0 006 0 26 10 ;
(ii) is installed in regional Victoria:
( ) [ ] e B Bs × ⋅ × ⋅ × ⋅ − ⋅ 2775 0 + 0573 0 006 0 26 10 ;
4A Regional factor: 1.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
4A At the beginning of the day on which the gas or liquefied
petroleum gas water heater, as modified by the installed
product, is first able to produce and deliver water heated
by solar energy.
__________________
Sch. 4
-- 29 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
25
SCHEDULE 5
Regulation 6(e)
HIGH EFFICIENCY DUCTED GAS HEATER REPLACING A
DUCTED GAS HEATER
Prescribed activity under regulation 6(e): Decommissioning a ducted gas
space heater and installing a product that complies with the criteria specified
in Part A of Schedule 5.
PART A—CRITERIA
Item
5A Ducted gas heater certified by an accredited body to
achieve a minimum 5 star rating when tested and rated in
accordance with AS 4556—2000 with a minimum rated
output heating capacity of 10 kW as determined in
accordance with AS 4556—2000 and listed in the ESC
register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of a ducted gas space heater and the
installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 5
-- 30 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
26
The following are the abatement factors and regional factors for
an item in Part A:
Item
5A Abatement factor:
(a) If the product has a rated output heating capacity of
not less than 10 and not more than 18 kW
as determined in accordance with AS 4556—2000
and has a star rating determined in accordance with
AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 7⋅74;
(ii) 5⋅5 or more: 9⋅67;
(b) If the product has a rated output heating capacity of
more than 18kW and not more than 28 kW
as determined in accordance with AS 4556—2000
and has a star rating determined in accordance with
AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 9⋅76;
(ii) 5⋅5 or more: 12⋅20;
(c) If the product has a rated output heating capacity of
more than 28 kW as determined in accordance with
AS 4556—2000 and has a star rating determined in
accordance with AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 12⋅16;
(ii) 5⋅5 or more: 15⋅20.
5A Regional factor:
(a) If the product is installed in metropolitan
Victoria: 1;
(b) If the product is installed in regional
Victoria—climatic region Mild: 1;
Sch. 5
-- 31 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
27
(c) If the product is installed in regional
Victoria—climatic region Cold: 1⋅61;
(d) If the product is installed in regional
Victoria—climatic region Hot: 0⋅71.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
5A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver ducted gas heating and the day on which the
ducted gas space heater is decommissioned.
__________________
Sch. 5
-- 32 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
28
SCHEDULE 6
Regulation 6(f)
HIGH EFFICIENCY DUCTED GAS HEATER REPLACING A
CENTRAL ELECTRIC RESISTANCE HEATER
Prescribed activity under regulation 6(f): Decommissioning a central electric
resistance heater that provides heating to a space with a floor area of at least
100m 2 and installing a product that complies with the criteria specified in
Part A of Schedule 6.
PART A—CRITERIA
Item
6A Ducted gas heater certified by an accredited body to
achieve a minimum 5 star rating when tested and rated in
accordance with AS 4556—2000 with a minimum rated
output heating capacity of 10 kW as determined in
accordance with AS 4556—2000 and listed in the ESC
register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
decommissioning of a central electric resistance heater and the
installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 6
-- 33 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
29
The following are the abatement factors and regional factors for
each item in Part A:
Item
6A Abatement factor:
(a) If the product has a rated output heating capacity of
not less than 10 and not more than 18 kW as
determined in accordance with AS 4556—2000 and
has a star rating determined in accordance with
AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 119⋅43;
(ii) 5⋅5 or more: 121⋅44;
(b) If the product has a rated output heating capacity of
more than 18 and not more than 28 kW as
determined in accordance with AS 4556—2000 and
has a star rating determined in accordance with
AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 151⋅07;
(ii) 5⋅5 or more: 153⋅61;
(c) If the product has a rated output heating capacity of
more than 28 kW as determined in accordance with
AS 4556—2000 and has a star rating determined in
accordance with AS 4556—2000 of—
(i) not less than 5⋅0 and not more
than 5⋅49: 188⋅48;
(ii) 5⋅5 or more: 191⋅66.
6A Regional factor:
(a) If the product is installed in metropolitan
Victoria: 1;
(b) If the product is installed in regional
Victoria—climatic region Mild: 1⋅08;
Sch. 6
-- 34 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
30
(c) If the product is installed in regional
Victoria—climatic region Cold: 1⋅74;
(d) If the product is installed in regional
Victoria—climatic region Hot: 0⋅76.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
6A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver ducted gas heating and the day on which the
central electric resistance heater is decommissioned.
__________________
Sch. 6
-- 35 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
31
SCHEDULE 7
Regulation 6(g)
HIGH EFFICIENCY DUCTED AIR TO AIR HEAT PUMP
REPLACING A DUCTED AIR TO AIR HEAT PUMP
Prescribed activity under regulation 6(g): If the residential premises are in a
non-gas reticulated area, decommissioning a ducted air to air heat pump and
installing a product that complies with the criteria specified in Part A of
Schedule 7.
PART A—CRITERIA
Item
7A A product complying with the MEPS requirement set out
in AS/NZS 3823.2:2005, achieving a minimum
coefficient of performance of 3⋅5 when tested in
accordance with AS/NZS 3823.1.2:2001 or
AS/NZS 3823.3.2002 and a minimum rated output heating
capacity of 10kW as determined in accordance with
AS 3823.1.2: 2001 at the H1 temperature condition and
listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of a ducted air to air heat pump and the
installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 7
-- 36 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
32
The following are the abatement factors and regional factors for
each item in Part A:
Item
7A Abatement factor:
(a) If the product provides a rated output heating
capacity of not less than 10 and not more than
18 kW as determined in accordance with
AS/NZS 3823.1.2:2001 at the H1 temperature
condition and has a coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 3⋅22;
(ii) not less than 4 and not more
than 4⋅49: 8⋅45;
(iii) not less than 4⋅5 and not more
than 4⋅99: 12⋅51;
(iv) 5 or more: 15⋅77;
(b) If the product provides a rated output heating
capacity of more than 18 and not more than 28 kW
as determined in accordance with AS/NZS 3823.1.2:
2001 at the H1 temperature condition and has a
coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 4⋅07;
(ii) not less than 4 and not more
than 4⋅49: 10⋅68;
(iii) not less than 4⋅5 and not more
than 4⋅99: 15⋅83;
(iv) 5 or more: 19⋅94;
Sch. 7
-- 37 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
33
(c) If the product provides a rated output heating
capacity of more than 28 kW as determined in
accordance with AS/NZS 3823.1.2:2001 at the
H1 temperature condition and has a coefficient of
performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 5⋅08;
(ii) not less than 4 and not more
than 4⋅49: 13⋅33;
(iii) not less than 4⋅5 and not more
than 4⋅99: 19⋅75;
(iv) 5 or more: 24⋅88.
7A Regional factor:
(a) If the product is installed in metropolitan
Victoria: 1;
(b) If the product is installed in regional
Victoria—climatic region Mild: 1⋅06;
(c) If the product is installed in regional
Victoria—climatic region Cold: 1⋅71;
(d) If the product is installed in regional
Victoria—climatic region Hot: 0⋅74.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
7A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver heating and the day on which the ducted air to air
heat pump is decommissioned.
__________________
Sch. 7
-- 38 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
34
SCHEDULE 8
Regulation 6(h)
HIGH EFFICIENCY DUCTED AIR TO AIR HEAT PUMP
REPLACING CENTRAL ELECTRIC RESISTANCE HEATER
Prescribed activity under regulation 6(h): If the residential premises are in a
non-gas reticulated area, decommissioning a central electric resistance
heater that provides heating to a space with a floor area of at least 100m 2
and installing a product that complies with the criteria specified in Part A of
Schedule 8.
PART A—CRITERIA
Item
8A A product complying with the MEPS requirement set out
in AS/NZS 3823.2:2005, achieving a minimum coefficient
of performance of 3⋅5 when tested in accordance with
AS/NZS 3823.1.2:2001 or AS/NZS 3823.3.2002 and a
minimum rated output heating capacity of 10 kW as
determined in accordance with AS 3823.1.2:2001 at the
H1 temperature condition and listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of a central electric resistance heater and
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
Sch. 8
-- 39 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
35
The following are the abatement factors and regional factors for
each item in Part A:
Item
8A Abatement factor:
(a) If the product provides a rated output heating
capacity of not less than 10 and not more than
18 kW as determined in accordance with
AS/NZS 3823.1.2:2001 at the H1 temperature
condition and has a coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 98⋅0;
(ii) not less than 4 and not more
than 4⋅49: 104⋅2;
(iii) not less than 4⋅5 and not more
than 4⋅99: 108⋅9;
(iv) 5 or more: 112⋅7;
(b) If the product provides a rated output heating
capacity of more than 18 and not more than 28 kW
as determined in accordance with AS/NZS 3823.1.2:
2001 at the H1 temperature condition and has a
coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 124⋅1;
(ii) not less than 4 and not more
than 4⋅49: 131⋅9;
(iii) not less than 4⋅5 and not more
than 4⋅99: 137⋅9;
(iv) 5 or more: 142⋅7;
Sch. 8
-- 40 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
36
(c) If the product provides a rated output heating
capacity of more than 28 kW as determined in
accordance with AS/NZS 3823.1.2: 2001 at the
H1 temperature condition and has a coefficient of
performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 156⋅6;
(ii) not less than 4 and not more
than 4⋅49: 166⋅1;
(iii) not less than 4⋅5 and not more
than 4⋅99: 173⋅4;
(iv) 5 or more: 179⋅2.
8A Regional factor:
(a) If the product is installed in metropolitan
Victoria: 1⋅00;
(b) If the product is installed in regional
Victoria—climatic region Mild: 1⋅06;
(c) If the product is installed in regional
Victoria—climatic region Cold: 1⋅75;
(d) If the product is installed in regional
Victoria—climatic region Hot: 0⋅67.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
8A At the beginning of the day which is the later of the day on
which the installed product is first able to produce and
deliver heating and the day on which the central electric
resistance heater is decommissioned.
__________________
Sch. 8
-- 41 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
37
SCHEDULE 9
Regulation 6(i)
GAS OR LIQUEFIED PETROLEUM GAS SPACE HEATER
Prescribed activity under regulation 6(i): Installing a gas or liquefied
petroleum gas space heater that is flued and complies with the criteria
specified in Part A of Schedule 9.
PART A—CRITERIA
Item
9A A product certified by an accredited body, achieving a
minimum energy star rating of 4 when tested and rated to
AS 4553—2000 or AS 4553—2008, with a minimum
rated output heating capacity of 2 kW as determined in
accordance with AS 4553—2000 or AS 4553—2008 and
listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
The following are the abatement factors and regional factors for
each item in Part A:
9A Abatement factor:
(a) If the product provides a rated output heating
capacity of not less than 2 and not more than 3 kW
as determined in accordance with AS 4553—2000
and has an energy star rating determined in
accordance with AS 4553—2000 of—
Sch. 9
-- 42 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
38
(i) not less than 4⋅0 and not more
than 4⋅9: 4⋅32;
(ii) 5 or more: 4⋅83;
(b) If the product provides a rated output heating
capacity of more than 3 and not more than 6 kW as
determined in accordance with AS 4553—2000 and
has an energy star rating determined in accordance
with AS 4553—2000 of—
(i) not less than 4.0 and not more
than 4⋅9: 8⋅19;
(ii) 5 or more: 9⋅17;
(c) If the product provides a rated output heating
capacity of more than 6 kW as determined in
accordance with AS 4553—2000 and has an energy
star rating when determined in accordance with
AS 4553—2000 of—
(i) not less than 4⋅0 and not more
than 4⋅9: 10⋅22;
(ii) 5 or more: 11⋅44.
9A Regional factor:
(a) If the product has an energy star rating determined in
accordance with AS 4553—2000 of not less than 4⋅0
and not more than 4⋅9 and—
(i) is installed in metropolitan Victoria: 1⋅00;
(ii) is installed in regional Victoria—
climatic region Mild: 0⋅32;
(iii) is installed in regional Victoria—
climatic region Cold: 0⋅51;
(iv) is installed in regional Victoria—
climatic region Hot: 0⋅22;
Sch. 9
-- 43 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
39
(b) If the product has an energy star rating determined in
accordance with AS 4553—2000 of 5⋅0 or more
and—
(i) is installed in metropolitan Victoria: 1⋅00;
(ii) is installed in regional Victoria—
climatic region Mild: 0⋅39;
(iii) is installed in regional Victoria—
climatic region Cold: 0⋅63;
(iv) is installed in regional Victoria—
climatic region Hot: 0⋅27.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
9A At the beginning of the day on which the installed product
is first able to produce and deliver heating.
__________________
Sch. 9
-- 44 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
40
SCHEDULE 10
Regulation 6(j)
SPACE AIR TO AIR HEAT PUMP
Prescribed activity under regulation 6(j): If the residential premises are in a
non-gas reticulated area, installing a space air to air heat pump that
complies with the criteria specified in Part A of Schedule 10.
PART A—CRITERIA
Item
10A A product complying with the MEPS requirement set out
in AS/NZS 3823.2: 2005, achieving a minimum
coefficient of performance of 3⋅5 when tested in
accordance with AS/NZS 3823.1.1:1998 and a minimum
rated output heating capacity of 2 kW as determined in
accordance with AS/NZS 3823.1.1:1998 at the
H1 temperature condition and listed in the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
10A Abatement factor:
(a) If the product provides a rated output heating
capacity of not less than 2 and not more than
3 kW as determined in accordance with
Sch. 10
-- 45 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
41
AS/NZS 3823.1.1: 1998 at the H1 temperature
condition and has a coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 5⋅21;
(ii) not less than 4 and not more than 4⋅49: 6⋅13;
(iii) not less than 4⋅5 and not more
than 4⋅99: 6⋅85;
(iv) 5 or more: 7⋅42;
(b) If the product provides a rated output heating
capacity of 3 or more and not more than 6 kW as
determined in accordance with
AS/NZS 3823.1.1:1998 at the H1 temperature
condition and has a coefficient of performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 9⋅89;
(ii) not less than 4 and not more
than 4⋅49: 11⋅65;
(iii) not less than 4⋅5 and not more
than 4⋅99: 13⋅01;
(iv) 5 or more: 14⋅09;
(c) If the product provides a rated output heating
capacity of more than 6 kW as determined in
accordance with AS/NZS 3823.1.1:1998 at the
H1 temperature condition and has a coefficient of
performance of—
(i) not less than 3⋅5 and not more
than 3⋅99: 12⋅55;
(ii) not less than 4 and not more
than 4⋅49: 14⋅68;
(iii) not less than 4⋅5 and not more
than 4⋅99: 16⋅33;
(iv) 5 or more: 17⋅65.
Sch. 10
-- 46 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
42
10A Regional factor:
(a) If the product has a coefficient of performance
of not less than 3⋅5 and is installed in
metropolitan Victoria: 1⋅00;
(b) If the product has a coefficient of performance of not
less than 3⋅5 and not more than 3⋅99 and—
(i) is installed in regional Victoria—
climatic region Mild: 0⋅07;
(ii) is installed in regional Victoria—
climatic region Cold: 0⋅18;
(iii) is installed in regional Victoria—
climatic region Hot: 0;
Note that a certificate cannot be created for a space air to air
heat pump installed in regional Victoria—climatic region Hot.
(c) If the product has a coefficient of performance of not
less than 4⋅0 and not more than 4⋅49 and—
(i) is installed in regional Victoria—
climatic region Mild: 0⋅22;
(ii) is installed in regional Victoria—
climatic region Cold: 0⋅39;
(iii) is installed in regional Victoria—
climatic region Hot: 0⋅09;
(d) If the product has a coefficient of performance of not
less than 4⋅5 and not more than 4⋅99 and—
(i) is installed in regional Victoria—
climatic region Mild: 0⋅34;
(ii) is installed in regional Victoria—
climatic region Cold: 0⋅58;
(iii) is installed in regional
Victoria—climatic region Hot: 0⋅20;
Sch. 10
-- 47 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
43
(e) If the product has a coefficient of performance of
5 or more and—
(i) is installed in regional Victoria—
climatic region Mild: 0⋅44;
(ii) is installed in regional Victoria—
climatic region Cold: 0⋅72;
(iii) is installed in regional Victoria—
climatic region Hot: 0⋅29.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
10A At the beginning of the day on which the installed product
is first able to produce and deliver heating.
__________________
Sch. 10
-- 48 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
44
SCHEDULE 11
Regulation 6(k)
CEILING INSULATION
Prescribed activity under regulation 6(k): Installing a product in accordance
with AS 3999—1992 in a ceiling area not previously insulated for a minimum
area of 20m 2
, being a product that complies with the criteria specified in
Part A of Schedule 11.
PART A—CRITERIA
Item
11A A product that complies, or two or more products that,
when installed together, comply with the performance
requirements of AS/NZS 4859.1:2002 (insulation
material) and achieves a minimum winter R-value of 3⋅5
when measured and labelled in accordance with
AS/NZS 4859.1:2002.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product or products referred to in an item in
Part A is determined by multiplying the area of insulation (m 2 )
by the abatement factor for that item by the regional factor
applying to the place where the product or products are installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
11A Abatement factor: 0⋅256;
11A Regional factor:
(a) If the product or products are installed in
metropolitan Victoria: 1⋅06;
Sch. 11
-- 49 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
45
(b) If the product or products are installed in
regional Victoria—climatic region Mild: 0⋅86;
(c) If the product or products are installed in
regional Victoria—climatic region Cold: 1⋅23;
(d) If the product or products are installed in
regional Victoria—climatic region Hot: 0⋅79.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
11A At the beginning of the day on which the installation of
the product or products is completed.
__________________
Sch. 11
-- 50 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
46
SCHEDULE 12
Regulation 6(l)
UNDER FLOOR INSULATION
Prescribed activity under regulation 6(l): Installing a product as under floor
insulation in accordance with AS 3999—1992 in respect of a floor area not
previously insulated for a minimum area of 20m 2, being a product that
complies with the criteria specified in Part A of Schedule 12.
PART A—CRITERIA
Item
12A A product that complies, or two or more products that,
when installed together, comply with the performance
requirements of AS/NZS 4859.1:2002 (insulation
material) and achieves a minimum winter R-value of
2⋅5 when measured and labelled in accordance with
AS/NZS 4859.1:2002.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product or products referred to in an item in
Part A is determined by multiplying the area of insulation (m 2 )
by the abatement factor for that item by the regional factor
applying to the place where the product or products are installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
12A Abatement factor: 0⋅073
Regional factor:
(a) If the product or products are installed in
metropolitan Victoria: 1⋅06;
Sch. 12
-- 51 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
47
(b) If the product or products are installed in
regional Victoria—climatic region Mild: 0⋅86;
(c) If the product or products are installed in
regional Victoria—climatic region Cold: 1⋅23;
(d) If the product or products are installed in
regional Victoria—climatic region Hot: 0⋅79.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
12A At the beginning of the day on which the installation of
the product or products is completed.
__________________
Sch. 12
-- 52 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
48
SCHEDULE 13
Regulation 6(m)
THERMALLY EFFICIENT WINDOW
Prescribed activity under regulation 6(m): Installing, in place of one or more
windows in an external wall, at least 5m2 of glazing or glazed product that
complies with the criteria specified in Part A of Schedule 13.
PART A—CRITERIA
Item
13A A product that complies with the performance
requirements of AS 2047—1999 and AS 1288—2006, has
a Total U-value of not more than 4, is WERS rated and
labelled to a minimum of 4 stars for heating and is listed in
the ESC register.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the area of glazing (m2 ) by the
abatement factor for that item and by the regional factor
applying to the place where the product is installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
13A Abatement factor:
If the product has a WERS rating on heating of—
(a) not less than 4⋅0 and not more than
4⋅9 stars: 0⋅394;
Sch. 13
-- 53 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
49
(b) not less than 5⋅0 and not more than
5⋅9 stars: 0⋅493;
(c) 6⋅0 or more stars: 0⋅591.
13A Regional factor:
(a) If the product or products are installed in
metropolitan Victoria: 1⋅03;
(b) If the product or products are installed in
regional Victoria—climatic region Mild: 0⋅92;
(c) If the product or products are installed in
regional Victoria—climatic region Cold: 1⋅41;
(d) If the product or products are installed in
regional Victoria—climatic region Hot: 0⋅74.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
13A At the beginning of the day on which the installation of
the product is completed.
__________________
Sch. 13
-- 54 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
50
SCHEDULE 14
Regulation 6(n)
INSTALLATION OF PRODUCT ON SINGLE GLAZED
WINDOW RAISING THERMAL EFFICIENCY
Prescribed activity under regulation 6(n): Installing on one or more single
glazed windows in an external wall for a minimum glazing area of 5m 2, a
product that complies with the criteria specified in Part A of Schedule 14.
PART A—CRITERIA
Item
14A A product that, when installed on a single glazed window,
results in a still air gap being created between the single
glazed window and the product and raises the thermal
efficiency performance of the window.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the area of glazing (m2 ) installed by
the abatement factor for that item and by the regional factor
applying to the place where the product is installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
14A Abatement factor:
(a) If the product is glass or acrylic: 0⋅213;
(b) If the product is window film: 0⋅071.
Sch. 14
-- 55 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
51
14A Regional factor:
(a) If the product is installed in
metropolitan Victoria: 1⋅03;
(b) If the product is installed in regional
Victoria—climatic region Mild: 0⋅92;
(c) If the product is installed in regional
Victoria—climatic region Cold: 1⋅41;
(d) If the product is installed in regional
Victoria—climatic region Hot: 0⋅74.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
14A At the beginning of the day on which the installation of
the product is completed.
__________________
Sch. 14
-- 56 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
52
SCHEDULE 15
Regulation 6(o)
WEATHER SEALING
Prescribed activity under regulation 6(o): In the same residential premises,
undertaking any one or more of the activities to restrict the airflow into
or out of the premises [referred to in subparagraphs (i) to (vi) of
regulation 6(o)] (not being an activity, or two or more activities that
together, result in the premises failing to receive natural air changes at a
rate of at least 0
⋅5 per hour or to comply with the minimum ventilation
requirements of Part 3.8.5 of the Building Code).
PART A—CRITERIA
Item
15A A door bottom sealing product or a product that is a light
weight self adhesive weather stripping product made of
foam, flexible plastic, polypropylene pile, rubber
compressible strip, fibrous seal or a similar product.
15B A product that is a light weight self adhesive weather
stripping product made of foam, flexible plastic,
polypropylene pile, rubber compressible strip, fibrous seal
or a similar product.
15C A product, being a ceiling or wall exhaust fan that is fitted
with a self-closing damper, flap, filter (for instance, of a
type commonly fitted to a kitchen range hood) or other
sealing product that can be closed to seal the exhaust of a
fan.
15D A product that is a self-closing damper, flap, filter (for
instance, of a type commonly fitted to a kitchen range
hood) or other sealing product that can be closed to seal
the exhaust of a fan.
15E A product capable of restricting the airflow into and out of
a ventilation opening.
Sch. 15
-- 57 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
53
15F A product that is capable of restricting air flow into or out
of a chimney or flue.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product or products installed in residential
premises in accordance with regulation 6(o) and this Schedule is
the sum of the figures obtained by multiplying the number of
activities undertaken in the premises under each item in Part A
by the abatement factor for that item (or, in the case of
item 15B, by the area in m2 of the window the frame of which is
sealed) and by the regional factor applying to the place where
the premises are situated.
The following are the abatement factors and regional factors for
each item in Part A:
Item
15A Abatement factor:
For each door: 0⋅371.
15B Abatement factor:
For each m2 of the window, the frame of which
is sealed: 0⋅025.
15C Abatement factor:
For each exhaust fan: 0⋅911.
15D Abatement factor:
For each exhaust fan: 0⋅911.
15E Abatement factor:
For each ventilation opening sealed or closed: 0⋅231.
15F Abatement factor:
For each chimney or flue in which a product is
installed: 5⋅130.
Sch. 15
-- 58 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
54
15A–15F Regional factor:
(a) If the prescribed activity is undertaken in
metropolitan Victoria: 1⋅03;
(b) If the prescribed activity is undertaken in
regional Victoria—climatic region Mild: 0⋅91;
(c) If the prescribed activity is undertaken in
regional Victoria—climatic region Cold: 1⋅30;
(d) If the prescribed activity is undertaken in
regional Victoria—climatic region Hot: 0⋅84.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
15A–15F At the beginning of the day on which the installation
of the product is completed or, in the case of the
installation of a product in place of a ceiling or wall
exhaust fan, at the beginning of the day which is the
later of the day on which the product is installed and
the day on which the ceiling or wall exhaust fan is
decommissioned.
__________________
Sch. 15
-- 59 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
55
SCHEDULE 16
Regulation 6(p)
LIGHTING
Prescribed activity under regulation 6(p): Installing lamps that comply with
the criteria specified in Part A of Schedule 16 and, where installed in place
of lamps that do not comply with those criteria, decommissioning those
lamps.
PART A—CRITERIA
Item
16A Installation of low energy GLS (general lighting service)
lamp, whether or not in place of an existing lamp or
lamps, being a product that—
(a) achieves minimum lighting source efficacy levels
of—
(i) 52 lumens/watt where light output is not less
than 650, and not more than, 850 lumens; or
(ii) 55 lumens/watt where light output is more
than 850 lumens; and
(b) has a minimum manufacturer's rated lifetime of
6000 hours; and
(c) if the lamp is to be installed in a dimmable circuit, is
approved by the manufacturer as suitable for such a
circuit.
16B Installation of low energy small lamp, whether or not in
place of an existing lamp or lamps, being a product that—
(a) achieves minimum lighting source efficacy levels
of—
(i) 40 lumens/watt where light output is not less
than 200 and not more than 350 lumens; or
Sch. 16
-- 60 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
56
(ii) 45 lumens/watt where light output is more
than 350, and not more than 550, lumens.
(b) has a minimum manufacturer's rated lifetime of
6000 hours; and
(c) if the lamp is to be installed in a dimmable circuit, is
approved by the manufacturer as suitable for such a
circuit.
16C Installation of low energy reflector lamp, whether or not in
place of an existing lamp or lamps, being a product that—
(a) achieves minimum lighting source efficacy levels of
25 lumens/watt; and
(b) has a minimum manufacturer's rated lifetime of
6000 hours; and
(c) if the lamp is to be installed in a dimmable circuit, is
approved by the manufacturer as suitable for such a
circuit.
16D Installation of low energy downlight, whether or not in
place of an existing lamp or lamps, being a product that—
(a) achieves minimum lighting source efficacy levels of
40 lumens/watt; and
(b) has a minimum manufacturer's rated lifetime of
6000 hours; and
(c) if the lamp is to be installed in a dimmable circuit, is
approved by the manufacturer as suitable for such a
circuit.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product or products referred to in an item in
Part A is determined by the sum of the figures obtained by
multiplying the number of lamps installed in the premises under
each item in Part A by the abatement factor for that item and by
Sch. 16
-- 61 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
57
the regional factor applying to the place where the premises are
situated.
The following are the abatement factors and regional factors for
each item in Part A:
Item
16A Abatement factor
(a) The abatement factor for a product that achieves a
minimum lighting source efficacy of—
(i) 52 lumens/watt where the light output is not
less than 650 lumens and not more than
850 lumens; or
(ii) 55 lumens/watt where the light output is more
than 850 lumens—
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅22
2 8000 or more and less than 10 000 0⋅29
3 10 000 or more and less than 12 000 0⋅36
4 12 000 or more and less than 15 000 0⋅44
5 15 000 or more 0⋅55
(b) The abatement factor for a product that achieves a
minimum lighting source efficacy of—
(i) 62 lumens/watt where the light output is not
less than 700 lumens and not more than
850 lumens; or
Sch. 16
-- 62 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
58
(ii) 66 lumens/watt where the light output is more
than 850 lumens—
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅23
2 8000 or more and less than 10 000 0⋅31
3 10 000 or more and less than 12 000 0⋅39
4 12 000 or more and less than 15 000 0⋅46
5 15 000 or more 0⋅58
16B Abatement factor
(a) The abatement factor for a product that achieves a
minimum lighting source efficacy of—
(i) 40 lumens/watt where the light output is not
less than 200 lumens and not more than
350 lumens; or
(ii) 45 lumens/watt where the light output is more
than 350 lumens and not more than
550 lumens—
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Sch. 16
-- 63 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
59
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅11
2 8000 or more and less than 10 000 0⋅15
3 10 000 or more and less than 12 000 0⋅19
4 12 000 or more and less than 15 000 0⋅22
5 15 000 or more 0⋅28
(b) The abatement factor for a product that achieves a
minimum lighting source efficacy of—
(i) 46 lumens/watt where the light output is not
less than 200 lumens and not more than
350 lumens; or
(ii) 52 lumens/watt where the light output is more
than 350 lumens and not more than
550 lumens—
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅12
2 8000 or more and less than 10 000 0⋅16
3 10 000 or more and less than 12 000 0⋅19
4 12 000 or more and less than 15 000 0⋅23
5 15 000 or more 0⋅29
Sch. 16
-- 64 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
60
16C Abatement factor
(a) The abatement factor for a product that achieves a
minimum lighting source efficacy of 25 lumens/watt
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅24
2 8000 or more and less than 10 000 0⋅32
3 10 000 or more and less than 12 000 0⋅40
4 12 000 or more and less than 15 000 0⋅48
5 15 000 or more 0⋅69
(b) The abatement factor for a product that achieves a
minimum lighting source efficacy of 30 lumens/watt
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅25
2 8000 or more and less than 10 000 0⋅33
3 10 000 or more and less than 12 000 0⋅42
4 12 000 or more and less than 15 000 0⋅50
5 15 000 or more 0⋅62
Sch. 16
-- 65 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
61
16D Abatement factor
(a) The abatement factor for a product that achieves a
minimum lighting source efficacy of 40 lumens/watt
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅18
2 8000 or more and less than 10 000 0⋅24
3 10 000 or more and less than 12 000 0⋅30
4 12 000 or more and less than 15 000 0⋅36
5 15 000 or more 0⋅46
(b) The abatement factor for a product that achieves a
minimum lighting source efficacy of 48 lumens/watt
and has a manufacturer's rated lifetime of a number
of hours in the range specified in an item in
column 1 of the Table below is the factor shown in
column 2 of that Table.
Item
Column 1
Hours
Column 2
Abatement
factor
1 6000 or more and less than 8000 0⋅20
2 8000 or more and less than 10 000 0⋅26
3 10 000 or more and less than 12 000 0⋅33
4 12 000 or more and less than 15 000 0⋅39
5 15 000 or more 0⋅49
Sch. 16
-- 66 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
62
16A–16D Regional factor:
(a) If the product or products are installed in
metropolitan Victoria: 0⋅98;
(b) If the product or products are installed in
regional Victoria: 1⋅04.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
16A–16D At the beginning of the day which is the later of the
day on which the installation of the product or
products is completed and, where the product or
products are installed in place of lamps that do not
comply with the criteria in Part A, the day on which
those lamps are decommissioned.
__________________
Sch. 16
-- 67 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
63
SCHEDULE 17
Regulation 6(q)
LOW FLOW SHOWER ROSE
Prescribed activity under regulation 6(q): Decommissioning a non-low flow
shower rose (not being a shower rose rated as having a 3 star or higher
water efficiency when assessed and labelled in accordance with
AS/NZS 6400:2005) and installing a low flow shower rose that complies
with the criteria specified in Part A of Schedule 17.
PART A—CRITERIA
Item
17A A product complying with the requirements of
AS/NZS 3662:2005 and that achieves a minimum 3 star
rating when assessed and labelled in accordance with
AS/NZS 6400:2005.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the decommissioning of a non-low flow shower rose and the
installation of a product referred to in an item in Part A is
determined by multiplying the number of products installed
(not being more than 2) by the abatement factor for that item
and multiplying the result by the regional factor applying to the
place where the product is installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
17A Abatement factor: 2⋅14.
Sch. 17
-- 68 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
64
17A Regional factor:
(a) If the product is installed in metropolitan
Victoria: 0⋅85;
(b) If the product is installed in regional Victoria: 1⋅04.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
17A At the beginning of the day which is the later of the day on
which the installation of the product is completed and the
day on which the non-low flow shower rose is
decommissioned.
__________________
Sch. 17
-- 69 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
65
SCHEDULE 18
Regulation 6(r)
HIGH EFFICIENCY REFRIGERATORS AND FREEZERS
Prescribed activity under regulation 6(r): Installing (purchasing) a high
efficiency refrigerator or high efficiency freezer that complies with an item in
Part A of Schedule 18.
PART A—CRITERIA
Item
18A Single door refrigerator listed in the ESC register—
(a) being a Group 1 refrigerator as defined by
AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and
(b) having a total volume as determined in accordance
with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007
of not less than 100 litres and not more than
500 litres; and
(c) having a minimum star rating of 6⋅0 as determined
in accordance with AS/NZS 4474.2:2001.
18B Two door refrigerator listed in the ESC register—
(a) being a Group 4, 5B, 5S or 5T refrigerator as
defined by AS/NZS 4474.1:1997 or
AS/NZS 4474.1:2007; and
(b) having a total volume as determined in accordance
with AS/NZS 4474.1:1997 or AS/NZS 4474.1.2007
of not less than 100 litres and not more than
700 litres; and
(c) having a minimum star rating of 4⋅5 as determined
in accordance with AS/NZS 4474.2:2001.
18C Chest freezer listed in the ESC register—
(a) being a Group 6C product as defined by
AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and
Sch. 18
-- 70 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
66
(b) having a total volume as determined in accordance
with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007
of not less than 100 litres and not more than
700 litres; and
(c) having a minimum star rating of 3⋅5 as determined
in accordance with AS/NZS 4474.2:2001.
18D Upright freezer listed in the ESC register—
(a) being a Group 6U or 7 product as defined by
AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and
(b) having a total volume as determined in accordance
with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007
of not less than 100 litres and not more than
400 litres; and
(c) having a minimum star rating of 4⋅5 as determined
in accordance with AS/NZS 4474.2:2001.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the installation of a product referred to in an item in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the product is
installed.
The following are the abatement factors and regional factors for
each item in Part A:
Item
18A Abatement factor:
{[0⋅5228 × (368 + 0⋅892 × Vff)] – CEC} × 0⋅01392
where Vff is the volume in litres of the fresh food
compartment of the product and CEC is the comparative
energy consumption specified on the energy rating label as
defined by AS/NZS 4474.2:2001.
Sch. 18
-- 71 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
67
18B Abatement factor:
{[0⋅4333 × (465 + 1⋅378 × (V ff + 1⋅6 × V fr))] – CEC} × 0⋅01392
where Vff is the volume in litres of the fresh food
compartment of the product, Vfr is the volume of the
freezer compartment and CEC is the comparative energy
consumption specified on the energy rating label as
defined by AS/NZS 4474.2:2001.
18C Abatement factor:
{[0⋅6889 × (248 + 1⋅072 × Vfr)] – CEC] × 0⋅01719
where Vfr is the volume of the freezer compartment and
CEC is the comparative energy consumption specified on
the energy rating label as defined by
AS/NZS 4474.2:2001.
18D Abatement factor:
{[0⋅5007 × (439 +1⋅632 × Vfr)] – CEC} × 0⋅01719
where Vfr is the volume of the freezer compartment and
CEC is the comparative energy consumption specified on
the energy rating label as defined by
AS/NZS 4474.2:2001.
18A–18D Regional factor:
(a) If the product is installed in metropolitan
Victoria: 0⋅98;
(b) If the product is installed in regional Victoria: 1⋅04.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
18A–18D At the beginning of the day on which the installation
of the product is completed.
__________________
Sch. 18 Sch. 18
-- 72 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
68
SCHEDULE 19
Regulation 6(s)
DESTRUCTION OF PRE-1996 REFRIGERATOR OR
FREEZER
Prescribed activity under regulation 6(s): Removing from the residential
premises a refrigerator or freezer manufactured before 1996 and in working
order and destroying the refrigerator or freezer in accordance with the
criteria specified in Part A of Schedule 19.
PART A—CRITERIA
Item
19A Destruction by the disposal, in accordance with the Ozone
Protection and Synthetic Greenhouse Gas Management
Act 1989 of the Commonwealth, of scheduled substances
(within the meaning of that Act) contained in the
refrigerator or freezer manufactured before 1996 and
removed from residential premises.
PART B—CALCULATION OF CARBON DIOXIDE
EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the
carbon dioxide equivalent of greenhouse gases to be reduced by
the removal and destruction of an item referred to in Part A is
determined by multiplying the abatement factor for that item by
the regional factor applying to the place where the residential
premises from which the item is removed are situated.
The following are the abatement factors and regional factors for
each item in Part A:
Item
19A Abatement factor:
(a) Single door refrigerator or freezer: 3⋅25;
(b) Two door refrigerator or freezer: 5⋅82.
Sch. 19
-- 73 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
69
19A Regional factor:
(a) If the residential premises from which the
item is removed are in metropolitan Victoria: 0⋅98;
(b) If the residential premises from which the
item is removed are in regional Victoria: 1⋅04.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Item
19A At the beginning of the day which is the later of the day on
which the refrigerator or freezer is removed from
residential premises and the day on which it is destroyed.
__________________
Sch. 19
-- 74 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
70
SCHEDULE 20
Regulation 4
DATA TABLE
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
1 3000 Metropolitan Yes Metropolitan
2 3001 Metropolitan Yes Metropolitan
3 3002 Metropolitan Yes Metropolitan
4 3003 Metropolitan Yes Metropolitan
5 3005 Metropolitan Yes Metropolitan
6 3006 Metropolitan Yes Metropolitan
7 3008 Metropolitan No Metropolitan
8 3010 Metropolitan Yes Metropolitan
9 3011 Metropolitan Yes Metropolitan
10 3012 Metropolitan Yes Metropolitan
11 3013 Metropolitan Yes Metropolitan
12 3015 Metropolitan Yes Metropolitan
13 3016 Metropolitan Yes Metropolitan
14 3018 Metropolitan Yes Metropolitan
15 3019 Metropolitan Yes Metropolitan
16 3020 Metropolitan Yes Metropolitan
17 3021 Metropolitan Yes Metropolitan
18 3022 Metropolitan Yes Metropolitan
19 3023 Metropolitan Yes Metropolitan
20 3024 Metropolitan Yes Metropolitan
21 3025 Metropolitan Yes Metropolitan
22 3026 Metropolitan Yes Metropolitan
23 3027 Metropolitan Yes Metropolitan
24 3028 Metropolitan Yes Metropolitan
Sch. 20
-- 75 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
71
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
25 3029 Metropolitan Yes Metropolitan
26 3030 Metropolitan Yes Metropolitan
27 3031 Metropolitan Yes Metropolitan
28 3032 Metropolitan Yes Metropolitan
29 3033 Metropolitan Yes Metropolitan
30 3034 Metropolitan Yes Metropolitan
31 3036 Metropolitan Yes Metropolitan
32 3037 Metropolitan Yes Metropolitan
33 3038 Metropolitan Yes Metropolitan
34 3039 Metropolitan Yes Metropolitan
35 3040 Metropolitan Yes Metropolitan
36 3041 Metropolitan Yes Metropolitan
37 3042 Metropolitan Yes Metropolitan
38 3043 Metropolitan Yes Metropolitan
39 3044 Metropolitan Yes Metropolitan
40 3045 Metropolitan Yes Metropolitan
41 3046 Metropolitan Yes Metropolitan
42 3047 Metropolitan Yes Metropolitan
43 3048 Metropolitan Yes Metropolitan
44 3049 Metropolitan Yes Metropolitan
45 3050 Metropolitan Yes Metropolitan
46 3051 Metropolitan Yes Metropolitan
47 3052 Metropolitan Yes Metropolitan
48 3053 Metropolitan Yes Metropolitan
49 3054 Metropolitan Yes Metropolitan
50 3055 Metropolitan Yes Metropolitan
51 3056 Metropolitan Yes Metropolitan
52 3057 Metropolitan Yes Metropolitan
Sch. 20
-- 76 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
72
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
53 3058 Metropolitan Yes Metropolitan
54 3059 Metropolitan Yes Metropolitan
55 3060 Metropolitan Yes Metropolitan
56 3061 Metropolitan Yes Metropolitan
57 3062 Metropolitan Yes Metropolitan
58 3063 Metropolitan Yes Metropolitan
59 3064 Metropolitan Yes Metropolitan
60 3065 Metropolitan Yes Metropolitan
61 3066 Metropolitan Yes Metropolitan
62 3067 Metropolitan Yes Metropolitan
63 3068 Metropolitan Yes Metropolitan
64 3070 Metropolitan Yes Metropolitan
65 3071 Metropolitan Yes Metropolitan
66 3072 Metropolitan Yes Metropolitan
67 3073 Metropolitan Yes Metropolitan
68 3074 Metropolitan Yes Metropolitan
69 3075 Metropolitan Yes Metropolitan
70 3076 Metropolitan Yes Metropolitan
71 3078 Metropolitan Yes Metropolitan
72 3079 Metropolitan Yes Metropolitan
73 3081 Metropolitan Yes Metropolitan
74 3082 Metropolitan Yes Metropolitan
75 3083 Metropolitan Yes Metropolitan
76 3084 Metropolitan Yes Metropolitan
77 3085 Metropolitan Yes Metropolitan
78 3086 Metropolitan Yes Metropolitan
79 3087 Metropolitan Yes Metropolitan
80 3088 Metropolitan Yes Metropolitan
Sch. 20
-- 77 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
73
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
81 3089 Metropolitan Yes Metropolitan
82 3090 Metropolitan Yes Metropolitan
83 3091 Metropolitan Yes Metropolitan
84 3093 Metropolitan Yes Metropolitan
85 3094 Metropolitan Yes Metropolitan
86 3095 Metropolitan Yes Metropolitan
87 3096 Metropolitan Yes Metropolitan
88 3097 Metropolitan Yes Metropolitan
89 3099 Metropolitan Yes Metropolitan
90 3101 Metropolitan Yes Metropolitan
91 3102 Metropolitan Yes Metropolitan
92 3103 Metropolitan Yes Metropolitan
93 3104 Metropolitan Yes Metropolitan
94 3105 Metropolitan Yes Metropolitan
95 3106 Metropolitan Yes Metropolitan
96 3107 Metropolitan Yes Metropolitan
97 3108 Metropolitan Yes Metropolitan
98 3109 Metropolitan Yes Metropolitan
99 3110 Metropolitan Yes Metropolitan
100 3111 Metropolitan Yes Metropolitan
101 3113 Metropolitan Yes Metropolitan
102 3114 Metropolitan Yes Metropolitan
103 3115 Metropolitan Yes Metropolitan
104 3116 Metropolitan Yes Metropolitan
105 3121 Metropolitan Yes Metropolitan
106 3122 Metropolitan Yes Metropolitan
107 3123 Metropolitan Yes Metropolitan
108 3124 Metropolitan Yes Metropolitan
Sch. 20
-- 78 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
74
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
109 3125 Metropolitan Yes Metropolitan
110 3126 Metropolitan Yes Metropolitan
111 3127 Metropolitan Yes Metropolitan
112 3128 Metropolitan Yes Metropolitan
113 3129 Metropolitan Yes Metropolitan
114 3130 Metropolitan Yes Metropolitan
115 3131 Metropolitan Yes Metropolitan
116 3132 Metropolitan Yes Metropolitan
117 3133 Metropolitan Yes Metropolitan
118 3134 Metropolitan Yes Metropolitan
119 3135 Metropolitan Yes Metropolitan
120 3136 Metropolitan Yes Metropolitan
121 3137 Metropolitan Yes Metropolitan
122 3138 Metropolitan Yes Metropolitan
123 3139 Metropolitan Yes Metropolitan
124 3140 Metropolitan Yes Metropolitan
125 3141 Metropolitan Yes Metropolitan
126 3142 Metropolitan Yes Metropolitan
127 3143 Metropolitan Yes Metropolitan
128 3144 Metropolitan Yes Metropolitan
129 3145 Metropolitan Yes Metropolitan
130 3146 Metropolitan Yes Metropolitan
131 3147 Metropolitan Yes Metropolitan
132 3148 Metropolitan Yes Metropolitan
133 3149 Metropolitan Yes Metropolitan
134 3150 Metropolitan Yes Metropolitan
135 3151 Metropolitan Yes Metropolitan
136 3152 Metropolitan Yes Metropolitan
Sch. 20
-- 79 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
75
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
137 3153 Metropolitan Yes Metropolitan
138 3154 Metropolitan Yes Metropolitan
139 3155 Metropolitan Yes Metropolitan
140 3156 Metropolitan Yes Metropolitan
141 3158 Metropolitan Yes Metropolitan
142 3159 Metropolitan Yes Metropolitan
143 3160 Metropolitan Yes Metropolitan
144 3161 Metropolitan Yes Metropolitan
145 3162 Metropolitan Yes Metropolitan
146 3163 Metropolitan Yes Metropolitan
147 3164 Metropolitan Yes Metropolitan
148 3165 Metropolitan Yes Metropolitan
149 3166 Metropolitan Yes Metropolitan
150 3167 Metropolitan Yes Metropolitan
151 3168 Metropolitan Yes Metropolitan
152 3169 Metropolitan Yes Metropolitan
153 3170 Metropolitan Yes Metropolitan
154 3171 Metropolitan Yes Metropolitan
155 3172 Metropolitan Yes Metropolitan
156 3173 Metropolitan Yes Metropolitan
157 3174 Metropolitan Yes Metropolitan
158 3175 Metropolitan Yes Metropolitan
159 3176 Metropolitan Yes Metropolitan
160 3177 Metropolitan Yes Metropolitan
161 3178 Metropolitan Yes Metropolitan
162 3179 Metropolitan Yes Metropolitan
163 3180 Metropolitan Yes Metropolitan
164 3181 Metropolitan Yes Metropolitan
Sch. 20
-- 80 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
76
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
165 3182 Metropolitan Yes Metropolitan
166 3183 Metropolitan Yes Metropolitan
167 3184 Metropolitan Yes Metropolitan
168 3185 Metropolitan Yes Metropolitan
169 3186 Metropolitan Yes Metropolitan
170 3187 Metropolitan Yes Metropolitan
171 3188 Metropolitan Yes Metropolitan
172 3189 Metropolitan Yes Metropolitan
173 3190 Metropolitan Yes Metropolitan
174 3191 Metropolitan Yes Metropolitan
175 3192 Metropolitan Yes Metropolitan
176 3193 Metropolitan Yes Metropolitan
177 3194 Metropolitan Yes Metropolitan
178 3195 Metropolitan Yes Metropolitan
179 3196 Metropolitan Yes Metropolitan
180 3197 Metropolitan Yes Metropolitan
181 3198 Metropolitan Yes Metropolitan
182 3199 Metropolitan Yes Metropolitan
183 3200 Metropolitan Yes Metropolitan
184 3201 Metropolitan Yes Metropolitan
185 3202 Metropolitan Yes Metropolitan
186 3204 Metropolitan Yes Metropolitan
187 3205 Metropolitan Yes Metropolitan
188 3206 Metropolitan Yes Metropolitan
189 3207 Metropolitan Yes Metropolitan
190 3211 Regional Yes Mild
191 3212 Regional Yes Mild
192 3214 Regional Yes Mild
Sch. 20
-- 81 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
77
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
193 3215 Regional Yes Mild
194 3216 Regional Yes Mild
195 3217 Regional Yes Mild
196 3218 Regional Yes Mild
197 3219 Regional Yes Mild
198 3220 Regional Yes Mild
199 3221 Regional Yes Mild
201 3222 Regional Yes Mild
202 3223 Regional Yes Mild
203 3224 Regional Yes Mild
204 3225 Regional Yes Mild
205 3226 Regional Yes Mild
206 3227 Regional Yes Mild
207 3228 Regional Yes Mild
208 3230 Regional Yes Mild
209 3231 Regional Yes Mild
210 3232 Regional No Mild
211 3233 Regional No Mild
212 3235 Regional No Mild
213 3236 Regional No Mild
214 3237 Regional No Mild
215 3238 Regional No Mild
216 3239 Regional No Mild
217 3240 Regional No Mild
218 3241 Regional No Mild
219 3242 Regional No Mild
220 3243 Regional No Mild
221 3249 Regional Yes Mild
Sch. 20
-- 82 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
78
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
222 3250 Regional Yes Mild
223 3251 Regional Yes Mild
224 3254 Regional No Mild
225 3260 Regional No Mild
226 3264 Regional No Mild
227 3265 Regional Yes Mild
228 3266 Regional Yes Mild
229 3267 Regional No Mild
230 3268 Regional No Mild
231 3269 Regional No Mild
232 3270 Regional No Mild
233 3271 Regional No Mild
234 3272 Regional No Mild
235 3273 Regional No Mild
236 3274 Regional No Mild
237 3275 Regional No Mild
238 3276 Regional No Mild
239 3277 Regional Yes Mild
240 3278 Regional No Mild
241 3279 Regional No Mild
242 3280 Regional Yes Mild
243 3281 Regional No Mild
244 3282 Regional Yes Mild
245 3283 Regional No Mild
246 3284 Regional No Mild
247 3285 Regional No Mild
248 3286 Regional No Mild
249 3287 Regional No Mild
Sch. 20
-- 83 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
79
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
250 3289 Regional No Cold
251 3292 Regional No Mild
252 3293 Regional No Cold
253 3294 Regional No Cold
254 3300 Regional Yes Cold
255 3301 Regional No Mild
256 3302 Regional No Mild
257 3303 Regional No Mild
258 3304 Regional No Mild
259 3305 Regional Yes Mild
260 3309 Regional No Mild
261 3310 Regional No Cold
262 3311 Regional No Cold
263 3312 Regional No Cold
264 3314 Regional No Cold
265 3315 Regional No Cold
266 3317 Regional No Cold
267 3318 Regional No Cold
268 3319 Regional No Cold
269 3321 Regional No Mild
270 3322 Regional No Mild
271 3323 Regional No Cold
272 3324 Regional No Cold
273 3325 Regional No Mild
274 3328 Regional No Mild
275 3329 Regional No Mild
276 3330 Regional No Cold
277 3331 Regional No Mild
Sch. 20
-- 84 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
80
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
278 3332 Regional No Mild
279 3333 Regional No Mild
280 3334 Regional No Cold
281 3335 Metropolitan Yes Metropolitan
282 3337 Metropolitan Yes Metropolitan
283 3338 Metropolitan Yes Metropolitan
284 3340 Regional Yes Mild
285 3341 Regional No Cold
286 3342 Regional Yes Cold
287 3345 Regional No Cold
288 3350 Regional Yes Cold
289 3351 Regional No Cold
290 3352 Regional Yes Cold
291 3353 Regional No Cold
292 3354 Regional No Cold
293 3355 Regional Yes Cold
294 3356 Regional Yes Cold
295 3357 Regional Yes Cold
296 3360 Regional No Cold
297 3361 Regional No Cold
298 3363 Regional No Cold
299 3364 Regional No Cold
300 3370 Regional No Cold
301 3371 Regional No Cold
302 3373 Regional No Cold
303 3375 Regional No Cold
304 3377 Regional Yes Cold
305 3378 Regional No Cold
Sch. 20
-- 85 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
81
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
306 3379 Regional No Cold
307 3380 Regional Yes Cold
308 3381 Regional No Cold
309 3384 Regional No Cold
310 3385 Regional No Cold
311 3387 Regional No Cold
312 3388 Regional No Cold
313 3390 Regional No Cold
314 3391 Regional No Cold
315 3392 Regional No Cold
316 3393 Regional No Cold
317 3395 Regional No Cold
318 3396 Regional No Cold
319 3400 Regional Yes Cold
320 3401 Regional Yes Cold
321 3402 Regional Yes Cold
322 3407 Regional No Cold
323 3409 Regional No Cold
324 3412 Regional No Cold
325 3413 Regional No Cold
326 3414 Regional No Cold
327 3415 Regional No Cold
328 3418 Regional No Cold
329 3419 Regional No Cold
330 3420 Regional No Cold
331 3423 Regional No Cold
332 3424 Regional No Cold
333 3427 Metropolitan Yes Metropolitan
Sch. 20
-- 86 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
82
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
334 3428 Metropolitan Yes Metropolitan
335 3429 Metropolitan Yes Metropolitan
336 3430 Regional No Mild
337 3431 Regional No Cold
338 3432 Regional No Cold
339 3434 Regional No Cold
340 3435 Regional No Cold
341 3437 Regional No Cold
342 3438 Regional No Cold
343 3440 Regional No Cold
344 3441 Regional No Cold
345 3442 Regional No Cold
346 3444 Regional Yes Cold
347 3446 Regional No Cold
348 3447 Regional No Cold
349 3448 Regional No Cold
350 3450 Regional Yes Cold
351 3451 Regional Yes Cold
352 3453 Regional No Cold
353 3458 Regional No Cold
354 3460 Regional Yes Cold
355 3461 Regional Yes Cold
356 3462 Regional No Cold
357 3463 Regional No Cold
358 3464 Regional Yes Cold
359 3465 Regional Yes Cold
360 3467 Regional No Cold
361 3468 Regional No Cold
Sch. 20
-- 87 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
83
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
362 3469 Regional No Cold
363 3472 Regional No Cold
364 3475 Regional No Cold
365 3478 Regional No Cold
366 3480 Regional No Cold
367 3482 Regional No Cold
368 3483 Regional No Cold
369 3485 Regional No Cold
370 3487 Regional No Hot
371 3488 Regional No Hot
372 3489 Regional No Hot
373 3490 Regional No Hot
374 3491 Regional No Hot
375 3494 Regional Yes Hot
376 3496 Regional Yes Hot
377 3498 Regional Yes Hot
378 3500 Regional Yes Hot
379 3501 Regional Yes Hot
380 3502 Regional Yes Hot
381 3505 Regional Yes Hot
382 3506 Regional No Hot
383 3507 Regional No Hot
384 3509 Regional No Hot
385 3512 Regional No Hot
386 3515 Regional No Cold
387 3516 Regional No Cold
388 3517 Regional No Cold
389 3518 Regional No Cold
Sch. 20
-- 88 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
84
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
390 3520 Regional No Cold
391 3521 Regional No Cold
392 3522 Regional No Cold
393 3523 Regional No Cold
394 3525 Regional No Cold
395 3527 Regional No Cold
396 3529 Regional No Hot
397 3530 Regional No Hot
398 3531 Regional No Hot
399 3533 Regional No Hot
400 3537 Regional No Hot
401 3540 Regional No Hot
402 3542 Regional No Hot
403 3544 Regional No Hot
404 3546 Regional No Hot
405 3549 Regional No Hot
406 3550 Regional Yes Cold
407 3551 Regional No Cold
408 3552 Regional No Cold
409 3554 Regional No Cold
410 3555 Regional Yes Cold
411 3556 Regional Yes Cold
412 3557 Regional No Cold
413 3558 Regional No Cold
414 3559 Regional No Cold
415 3561 Regional Yes Cold
416 3562 Regional No Cold
417 3563 Regional Yes Cold
Sch. 20
-- 89 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
85
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
418 3564 Regional Yes Cold
419 3565 Regional No Cold
420 3566 Regional Yes Hot
421 3567 Regional No Hot
422 3568 Regional No Hot
423 3570 Regional No Cold
424 3571 Regional No Cold
425 3572 Regional No Cold
426 3573 Regional No Cold
427 3575 Regional No Hot
428 3576 Regional No Hot
429 3579 Regional No Hot
430 3580 Regional No Hot
431 3581 Regional No Hot
432 3583 Regional No Hot
433 3584 Regional No Hot
434 3585 Regional No Hot
435 3588 Regional No Hot
436 3589 Regional No Hot
437 3590 Regional No Hot
438 3591 Regional No Hot
439 3594 Regional No Hot
440 3595 Regional No Hot
441 3596 Regional No Hot
442 3597 Regional No Hot
443 3599 Regional No Hot
444 3607 Regional No Cold
445 3608 Regional No Cold
Sch. 20
-- 90 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
86
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
446 3610 Regional Yes Cold
447 3612 Regional No Cold
448 3614 Regional No Cold
449 3616 Regional Yes Cold
450 3617 Regional No Cold
451 3618 Regional Yes Cold
452 3619 Regional No Cold
453 3620 Regional Yes Cold
454 3621 Regional Yes Cold
455 3622 Regional No Cold
456 3623 Regional Yes Cold
457 3624 Regional Yes Cold
458 3629 Regional Yes Cold
459 3630 Regional Yes Cold
460 3631 Regional Yes Cold
461 3632 Regional No Cold
462 3633 Regional No Cold
463 3634 Regional No Cold
464 3635 Regional No Cold
465 3636 Regional Yes Cold
466 3637 Regional No Cold
467 3638 Regional No Cold
468 3639 Regional No Cold
469 3640 Regional Yes Cold
470 3641 Regional Yes Cold
471 3643 Regional Yes Cold
472 3644 Regional Yes Cold
473 3646 Regional No Cold
Sch. 20
-- 91 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
87
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
474 3647 Regional No Cold
475 3649 Regional No Cold
476 3658 Regional Yes Cold
477 3659 Regional Yes Cold
478 3660 Regional Yes Cold
479 3661 Regional No Cold
480 3662 Regional No Cold
481 3663 Regional No Cold
482 3664 Regional No Cold
483 3665 Regional No Cold
484 3666 Regional Yes Cold
485 3669 Regional No Cold
486 3670 Regional No Cold
487 3671 Regional No Cold
488 3672 Regional Yes Cold
489 3673 Regional No Cold
490 3675 Regional No Cold
491 3676 Regional No Cold
492 3677 Regional Yes Cold
493 3678 Regional Yes Cold
494 3682 Regional No Cold
495 3683 Regional Yes Cold
496 3685 Regional Yes Cold
497 3687 Regional Yes Cold
498 3688 Regional No Cold
499 3689 Regional No Cold
500 3690 Regional Yes Cold
501 3691 Regional Yes Cold
Sch. 20
-- 92 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
88
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
502 3694 Regional No Cold
503 3695 Regional No Cold
504 3697 Regional No Cold
505 3698 Regional No Cold
506 3699 Regional No Cold
507 3700 Regional No Cold
508 3701 Regional No Cold
509 3704 Regional No Cold
510 3705 Regional No Cold
511 3707 Regional No Cold
512 3708 Regional No Cold
513 3709 Regional No Cold
514 3711 Regional No Cold
515 3712 Regional No Cold
516 3713 Regional No Cold
517 3714 Regional No Cold
518 3715 Regional No Cold
519 3717 Regional No Cold
520 3718 Regional No Cold
521 3719 Regional No Cold
522 3720 Regional No Cold
523 3722 Regional No Cold
524 3723 Regional No Cold
525 3724 Regional No Cold
526 3725 Regional No Cold
527 3726 Regional No Cold
528 3727 Regional No Cold
529 3728 Regional No Cold
Sch. 20
-- 93 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
89
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
530 3730 Regional Yes Cold
531 3732 Regional No Cold
532 3733 Regional No Cold
533 3735 Regional No Cold
534 3736 Regional No Cold
535 3737 Regional No Cold
536 3738 Regional No Cold
537 3739 Regional No Cold
538 3740 Regional No Cold
539 3741 Regional No Cold
540 3744 Regional No Cold
541 3746 Regional No Cold
542 3747 Regional No Cold
543 3749 Regional No Cold
544 3750 Regional Yes Mild
545 3751 Regional Yes Mild
546 3752 Regional Yes Mild
547 3753 Regional Yes Mild
548 3754 Regional Yes Mild
549 3755 Regional Yes Mild
550 3756 Regional Yes Mild
551 3757 Regional Yes Mild
552 3758 Regional No Mild
553 3759 Regional Yes Mild
554 3760 Regional Yes Mild
555 3761 Regional Yes Mild
556 3762 Regional No Cold
557 3763 Regional Yes Cold
Sch. 20
-- 94 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
90
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
558 3764 Regional Yes Cold
559 3765 Metropolitan Yes Metropolitan
560 3766 Regional Yes Cold
561 3767 Regional Yes Cold
562 3770 Regional Yes Cold
563 3775 Regional Yes Cold
564 3777 Regional Yes Cold
565 3778 Regional No Cold
566 3779 Regional No Cold
567 3781 Metropolitan Yes Metropolitan
568 3782 Metropolitan Yes Metropolitan
569 3783 Metropolitan Yes Metropolitan
570 3786 Regional Yes Cold
571 3787 Regional Yes Cold
572 3788 Regional Yes Cold
573 3789 Regional Yes Cold
574 3791 Metropolitan Yes Metropolitan
575 3792 Regional Yes Cold
576 3793 Regional Yes Cold
577 3795 Regional Yes Cold
578 3796 Regional Yes Cold
579 3797 Regional No Mild
580 3799 Regional No Cold
581 3800 Regional Yes Mild
582 3802 Metropolitan Yes Metropolitan
583 3803 Metropolitan Yes Metropolitan
584 3804 Metropolitan Yes Metropolitan
585 3805 Metropolitan Yes Metropolitan
Sch. 20
-- 95 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
91
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
586 3806 Metropolitan Yes Metropolitan
587 3807 Metropolitan Yes Metropolitan
588 3808 Metropolitan Yes Metropolitan
589 3809 Metropolitan Yes Metropolitan
590 3810 Metropolitan Yes Metropolitan
591 3812 Regional Yes Mild
592 3813 Regional Yes Mild
593 3814 Regional Yes Mild
594 3815 Regional Yes Mild
595 3816 Regional Yes Mild
596 3818 Regional Yes Mild
597 3820 Regional Yes Mild
598 3821 Regional No Mild
599 3822 Regional Yes Mild
600 3823 Regional Yes Mild
601 3824 Regional Yes Mild
602 3825 Regional Yes Mild
603 3831 Regional No Mild
604 3832 Regional No Mild
605 3833 Regional No Cold
606 3835 Regional No Mild
607 3840 Regional Yes Mild
608 3841 Regional No Mild
609 3842 Regional Yes Mild
610 3844 Regional Yes Mild
611 3847 Regional Yes Mild
612 3850 Regional Yes Mild
613 3851 Regional Yes Mild
Sch. 20
-- 96 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
92
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
614 3852 Regional Yes Mild
615 3853 Regional Yes Mild
616 3854 Regional No Mild
617 3856 Regional No Mild
618 3857 Regional No Mild
619 3858 Regional No Mild
620 3859 Regional No Mild
621 3860 Regional Yes Cold
622 3862 Regional No Cold
623 3864 Regional No Cold
624 3865 Regional No Mild
625 3869 Regional No Mild
626 3870 Regional No Mild
627 3871 Regional No Mild
628 3873 Regional No Mild
629 3874 Regional No Mild
630 3875 Regional No Mild
631 3878 Regional No Mild
632 3880 Regional No Mild
633 3882 Regional No Mild
634 3885 Regional No Mild
635 3886 Regional No Mild
636 3887 Regional No Mild
637 3888 Regional No Mild
638 3889 Regional No Cold
639 3890 Regional No Mild
640 3891 Regional No Mild
641 3892 Regional No Mild
Sch. 20
-- 97 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
93
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
642 3893 Regional No Cold
643 3895 Regional No Cold
644 3896 Regional No Cold
645 3898 Regional No Cold
646 3900 Regional No Cold
647 3902 Regional No Mild
648 3903 Regional No Mild
649 3904 Regional No Mild
650 3909 Regional No Mild
651 3910 Metropolitan Yes Metropolitan
652 3911 Metropolitan Yes Metropolitan
653 3912 Metropolitan Yes Metropolitan
654 3913 Metropolitan Yes Metropolitan
655 3915 Metropolitan Yes Metropolitan
656 3916 Metropolitan Yes Metropolitan
657 3918 Metropolitan Yes Metropolitan
658 3919 Metropolitan Yes Metropolitan
659 3920 Metropolitan Yes Metropolitan
660 3921 Regional Yes Mild
661 3922 Regional No Mild
662 3923 Regional No Mild
663 3925 Regional No Mild
664 3926 Regional Yes Mild
665 3927 Regional Yes Mild
666 3928 Regional Yes Mild
667 3929 Regional Yes Mild
668 3930 Regional Yes Mild
669 3931 Regional Yes Mild
Sch. 20
-- 98 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
94
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
670 3933 Regional Yes Mild
671 3934 Regional Yes Mild
672 3936 Regional Yes Mild
673 3937 Regional Yes Mild
674 3938 Regional Yes Mild
675 3939 Regional Yes Mild
676 3940 Regional Yes Mild
677 3941 Regional Yes Mild
678 3942 Regional Yes Mild
679 3943 Regional Yes Mild
680 3944 Regional Yes Mild
681 3945 Regional No Mild
682 3946 Regional No Cold
683 3950 Regional No Mild
684 3951 Regional No Mild
685 3953 Regional No Mild
686 3954 Regional No Mild
687 3956 Regional No Mild
688 3957 Regional No Mild
689 3958 Regional No Cold
690 3959 Regional No Mild
691 3960 Regional No Mild
692 3962 Regional No Mild
693 3964 Regional No Cold
694 3965 Regional No Mild
695 3966 Regional No Cold
696 3967 Regional No Cold
697 3971 Regional No Cold
Sch. 20
-- 99 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
95
Column 1 Column 2 Column 3 Column 4 Column 5
Item Postcode
Regional/
Metropolitan
Reticulated
Gas Climatic Region
698 3975 Metropolitan Yes Metropolitan
699 3976 Metropolitan Yes Metropolitan
700 3977 Metropolitan Yes Metropolitan
701 3978 Regional Yes Mild
702 3979 Regional No Mild
703 3980 Regional Yes Cold
704 3981 Regional Yes Cold
705 3984 Regional Yes Mild
706 3987 Regional Yes Mild
707 3988 Regional No Cold
708 3990 Regional No Mild
709 3991 Regional No Mild
710 3992 Regional No Mild
711 3995 Regional No Mild
712 3996 Regional No Mild
═══════════════
Sch. 20
-- 100 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
96
ENDNOTES
Table of Applied, Adopted or Incorporated Matter Required by the
Subordinate Legislation Regulations 2004
Note that the following table of applied, adopted or incorporated matter is
included in accordance with the requirements of regulation 5 of the Subordinate
Legislation Regulations 2004.
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
regulation 4 AS 4234—1994
Solar water heaters—
Domestic and heat pump—
Calculation of energy
consumption
The whole
regulation 4 Building Code of Australia meaning of
glazing as
defined in
Part 1.1 and as
used in Part 2.6
regulation 6(k) AS 3999—1992
Thermal insulation of
dwellings—Bulk insulation—
Installation requirements
The whole
regulation 6(l) AS 3999—1992
Thermal insulation of
dwellings—Bulk insulation—
Installation requirements
The whole
regulation 6(o) Building Code of Australia Part 3.8.5
regulation 6(q) AS/NZS 6400:2005
Water efficient products—
Rating and labelling
The whole
Schedule 1 AS 4234—1994
Solar water heaters—
Domestic and heat pump—
Calculation of energy
consumption
The whole as
modified by
Schedule 1,
Part A
Endnotes
-- 101 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
97
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Schedule 1 AS 4552/AG 102—2000
Gas Water Heaters
The whole
Schedule 1 AS 4552—2005
Gas fired water heaters for hot
water supply and/or central
heating
The whole
Schedule 1, Part A AS/NZS 2712:2007
Solar and heat pump water
heaters—Design and
construction
The whole
Schedule 2, Part A AS/NZS 2712:2007
Solar and heat pump water
heaters—Design and
construction
The whole
Schedule 2, Part A AS 4234—1994
Solar water heaters—
Domestic and heat pump—
Calculation of energy
consumption
The whole as
modified by
Schedule 2
Part A
Schedule 2, Part A Guidelines to calculate annual
solar energy savings for
domestic solar water heaters
produced by adding a Retrofit
Kit (collectors and pump) to
an existing tank, Version 5.1
October 2008, Sustainability
Victoria
The whole
Schedule 3, Part A AS/NZS 2712:2007
Solar and heat pump water
heaters—Design and
construction
The whole
-- 102 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
98
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Schedule 3 AS 4234—1994
Solar water heaters—
Domestic and heat pump—
Calculation of energy
consumption
The whole as
modified by
Schedule 3,
Part A
Schedule 4, Part A AS/NZS 2712:2007
Solar and heat pump water
heaters—Design and
construction
The whole
Schedule 4 AS 4234—1994
Solar water heaters—
Domestic and heat pump—
Calculation of energy
consumption
The whole as
modified by
Schedule 4,
Part A
Schedule 4 Guidelines to calculate annual
solar energy savings for
domestic solar water heaters
produced by adding a solar
preheater to an existing gas
hot water system, Version 2.3
October 2008, Sustainability
Victoria
The whole
Schedule 5 AS 4556—2000
(AG 106—2000) Indirect gas-
fired ducted air-heaters
The whole
Schedule 6 AS 4556—2000
(AG 106—2000) Indirect gas-
fired ducted air-heaters
The whole
Schedule 7 AS/NZS 3823.1.2:2001
Performance of electrical
appliances—Airconditioners
and heat pumps—Test
methods—Ducted
airconditioners and air-to-air
heat pumps—Testing and
rating for performance
The whole
-- 103 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
99
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Schedule 7, Part A AS/NZS 3823.2:2005
Performance of electrical
appliances—Airconditioners
and heat pumps—Energy
labelling and minimum energy
performance standard (MEPS)
requirements
The whole
Schedule 7, Part A AS/NZS 3823.3:2002
Performance of electrical
appliances—Airconditioners
and heat pumps—Performance
of electrical appliances—
Airconditioners and heat
pumps (MEPS)
The whole
Schedule 8 AS/NZS 3823.1.2:2001
Performance of electrical
appliances—Airconditioners
and heat pumps—Test
methods—Ducted
airconditioners and air-to-air
heat pumps—Testing and
rating for performance
The whole
Schedule 8, Part A AS/NZS 3823.2:2005
Performance of electrical
appliances—Airconditioners
and heat pumps—Energy
labelling and minimum energy
performance standard (MEPS)
requirements
The whole
Schedule 8, Part A AS/NZS 3823.3:2002
Performance of electrical
appliances—Airconditioners
and heat pumps—Performance
of electrical appliances—
Airconditioners and heat
pumps (MEPS)
The whole
-- 104 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
100
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Schedule 9 AS 4553—2000
(AG 103—2000) Gas space
heating appliances
The whole
Schedule 9 AS 4553—2008
Gas space heating appliances
The whole
Schedule 10, Part A AS/NZS 3823.2:2005
Performance of electrical
appliances—Airconditioners
and heat pumps—Energy
labelling and minimum energy
performance standard (MEPS)
requirements
The whole
Schedule 10 AS/NZS 3823.1.1:1998
Performance of electrical
appliances—Airconditioners
and heat pumps—Test
methods—Ducted
airconditioners and air-to-air
heat pumps—Testing and
rating for performance
The whole
Schedule 11 AS/NZS 4859.1:2002
Materials for the thermal
insulation of buildings—
General criteria and technical
provisions
The whole
Schedule 12 AS/NZS 4859.1:2002
Materials for the thermal
insulation of buildings—
General criteria and technical
provisions
The whole
Schedule 13 AS 2047—1999
Windows in buildings—
Selection and installation
The whole
-- 105 of 106 --
Victorian Energy Efficiency Target Regulations 2008
S.R. No. 158/2008
101
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Schedule 13 AS 1288—2006
Glass in buildings—Selection
and installation
The whole
Schedule 18 AS/NZS 4474.1:1997
Performance of household
electrical appliances—
Refrigerating appliances—
Energy consumption and
performance
The whole
Schedule 18 AS/NZS 4474.1:2007
Performance of household
electrical appliances—
Refrigerating appliances—
Energy consumption and
performance
The whole
Schedule 18 AS/NZS 4474.2:2001
Performance of household
electrical appliances—
Refrigerating appliances—
Energy labelling and
minimum energy standard
requirements
The whole
-- 106 of 106 --