Duffy v Sunshine Coast Regional Council & Anor [2015] QPEC 58 [2016] QPELR 118
PLANNING & ENVIRONMENT COURT
OF QUEENSLAND
CITATION: Duffy v Sunshine Coast Regional Council & Anor [2015]
QPEC 58
PARTIES: PETER ALAN DUFFY & YVONNE LYNETTE DUFFY
(appellants)
v
SUNSHINE COAST REGIONAL COUNCIL
(respondent)
and
NORTHERN SEQ DISTRIBUTOR-RETAILER
AUTHORITY (trading as UNITYWATER)
(co-respondent)
FILE NO/S: D 143 of 2012
PROCEEDING: Appeal
DELIVERED ON: 4 December 2015
DELIVERED AT: Maroochydore
HEARING DATE: 10 and 13 November 2014
JUDGE: Long SC DCJ
ORDER: Appeal dismissed and the respondent’s decision of 2 July
2012, is confirmed
CATCHWORDS: PLANNING AND ENVIRONMENT – APPEAL – Refusal of
development application for a reconfiguration of a lot –
Application for sub-division of land involving steep slopes and
landslide hazard – Whether conflict with Maroochy Plan 2000
– Whether conflict with Sunshine Coast Planning Scheme
2014 – Whether sufficient grounds to warrant approval despite
conflict
Legislation
Sustainable Planning Act 2009 (Qld) ss 314, 324, 326, 345,
461, 495, sch 3
Cases
Coty (England) Pty Ltd v Sydney City Council (1957) 2 LGRA
117
Drivetype Pty Ltd v Caboolture Shire Council [1995] QPLR
141
-- 1 of 38 --
2
Lewiac Pty Ltd v Gold Coast City Council (1996) 2 Qd R 266
Luke & Ors v Maroochy Shire Council and Watpac
Developments Pty Ltd [2003] QPELR 447
Vynotas Pty Ltd v BCC [2001] QPELR 14
Westfield Management Ltd v Pine Rivers Shire Council [2004]
QPELR 337
Yu Feng Pty Ltd v Maroochy Shire Council (1996) 92 LGERA
41
COUNSEL: D O’Brien QC and P Beehre for the Appellant
CL Hughes QC and N Kefford for the Respondent
SOLICITORS: Andrew Morris Legal for the Appellant.
Sunshine Coast Regional Council for the Respondent.
Introduction
[1] This matter concerns an appeal brought pursuant to s 461 of the Sustainable Planning
Act 2009 (“SPA”) and in respect of the decision of the respondent Council, made on
2 July 2012 (and notified by letter dated 5 July 2012), to refuse a development
application for a reconfiguration of Lot 10 on RP 803697 and located at 137 Jones
Road, Buderim (“the Land”). The Notice of Appeal was filed on 7 August 2012. The
development application had been lodged on 7 September 2011.
[2] The Land has an area of 8,471m2 and is located on the corner of Jones Road and
Lindsay Road.1 The Land is situated within the North Buderim area, which is
primarily comprised of single detached housing. There is a small convenience
shopping centre located approximately 150 metres to the north, on the corner of
Pittards Road and Jones Road, and a McDonald’s fast food outlet is located further
north on the corner of Maroochydore Road and Main Road.2 There are traffic signals
at the intersections of Jones Road with both Pittards Road and Maroochydore Road.
[3] To the east of the Land, across Jones Road, there is predominantly single detached
housing on conventional residential sized lots. To the north of the Land, across
Lindsay Road, is an electricity substation. To the west, also across Lindsay Road, is
generally vacant land leading to Martins Creek. To the south, there is a scattering of
residential properties on larger lots, and a recent subdivision (Birdwing Forest Place)
1 See Ex. 1.
2 Main Road is an extension of Jones Road.
-- 2 of 38 --
3
with lots in the order of 800m2. Adjacent to the south-east corner of the Land (on Lot
9), there is an existing Unitywater pump station. This is accessed off Jones Road and
an existing water main traverses the Land from the pump station, in a south-east
direction. This infrastructure is within an established easement over the Land, in
favour of the Council.
[4] The Land contains an existing dwelling, located in the north-eastern aspect of the site,
with access off Jones Road and into a part of it which is more gently sloped than much
of the remainder of it. Otherwise, the lot contains steeply sloping land in a
downwards direction generally from east to west, with some flattening on the western
side adjacent to Lindsay Road. The Land has been the subject of terracing and
installation of boulder and timber retaining walls. The Land also contains vegetation,
including some quite mature, tall trees which, as the respondent points out, the
geotechnical engineers agree are presently important in stabilising the steep slopes.
Otherwise, it may be noted that there are also some unsupported excavations of
between 1 and 1.5 metres in vertical height on the land and some large stockpiles of
uncontrolled fill of up to 2 metres in thickness.3
[5] The development application was lodged on or about 7 September 2011 and required
impact assessment.4 There were three properly made submissions, and in those
submissions reference was made to land instability.5
[6] The purpose of that application was to seek a development permit for the
reconfiguration of one lot into four lots, with an access easement. That application
was made under SPA and accordingly and pursuant to s 495(1) of SPA, this appeal is
conducted by way of hearing anew and therefore to be decided according to the facts
as they now exist.6 The appellants bear the onus of proof.7
[7] The application is now to be assessed by the Court, standing in the shoes of the
assessment manager and by reference to s 314 of SPA, which provides:
“314 Impact assessment—generally
(1) This section applies to any part of the application requiring
impact assessment.
3 Ex. 1, vol. 1, pp 121 and 152.
4 Ex. 1, vol. 1, pp 42 and 67.
5 Ex. 1, vol. 1, p 110.
6 Section 495(1) of SPA, and see R v Lukin ex parte Sunshine Pty Ltd [1967] Qd R 49, at 53.
7 Section 493(2) of SPA.
-- 3 of 38 --
4
(2) The assessment manager must assess the part of the application
against each of the following matters or things to the extent the
matter or thing is relevant to the development—
(a) The State planning regulatory provisions;
(b) The regional plan for a designated region, to the extent
it is not identified in the planning scheme as being
appropriately reflected in the planning scheme;
(c) If the assessment manager is not a local government—
the laws that are administered by, and the policies that
are reasonably identifiable as policies applied by, the
assessment manager and that are relevant to the
application;
Note—
However, if the chief executive is the assessment manager for
the application, see section 255B.
(d) State planning policies, to the extent the policies are not
identified in—
(i) Any relevant regional plan as being
appropriately reflected in the regional plan; or
(ii) The planning scheme as being appropriately
reflected in the planning scheme;
(e) A temporary local planning instrument;
(f) A preliminary approval to which section 242 applies;
(g) A planning scheme;
(h) for development not in a planning scheme area—any
planning scheme or temporary local planning
instrument for a planning scheme area that may be
materially affected by the development;
(i) If the assessment manager is an infrastructure
provider—the provider’s LGIP, if any.
Note—
See chapters 2 and 3 for particular provisions about the
relationship between the matters or things mentioned in subsection
(2).
(3) In addition to the matters or things against which the
assessment manager must assess the application under
subsection (2), the assessment manager must assess the part of
the application having regard to the following—
(a) The common material;
(b) Any development approval for, and any lawful use of,
premises the subject of the application or adjacent
premises;
(c) Any referral agency’s response for the application.”
-- 4 of 38 --
5
[8] The matter is to be decided in accordance with ss 324 and 326 of SPA and the relevant
provisions of the latter section should be specifically noted, as they are of some
importance to the outcome of this matter:
“326 Other decision rules
(1) The assessment manager’s decision must not conflict with a
relevant instrument unless—
…...
(b) there are sufficient grounds to justify the decision,
despite the conflict; ….
(2) In this section—
relevant instrument means a matter or thing mentioned in
section 313(2) or 314(2), other than a State planning regulatory
provision, against which code assessment or impact
assessment is carried out.”
[9] It is also of significance to note that for the purposes of application of s 326(1) (b),
the meaning of “grounds” is provided in Schedule 3 of SPA, as follows:
“1 Grounds means matters of public interest.
2 Grounds does not include the personal circumstances of an
applicant, owner or interested party.”
[10] Section 495(2) of SPA prescribes the applicable law to be applied. Relevantly, it is
provided that:
“(2) However, if the appellant is the applicant … for a development
application, the court—
(a) must decide the appeal based on the laws and policies
applying when the application was made, but may give
weight to any new laws and policies the court considers
appropriate; ...”
The issues
[11] Although the respondent refused the application on numerous grounds, including in
relation to visual amenity, character, environmental, stability, traffic and town
planning, subsequently to the initiation of the appeal, the respondent indicated that it
no longer contended that there were issues concerning visual amenity, character or
environmental matters which warranted refusal of the application. Further and at the
hearing of the appeal, it was indicated that traffic issues had also been resolved by the
-- 5 of 38 --
6
appellants’ agreement to conditions, which the respective retained traffic engineers
had identified would, if imposed, resolve any such safety concerns.8
[12] Accordingly, the outstanding issues to be determined in this appeal involve
geotechnical and town planning issues and particularly as to such issues turning on
the question of whether, from a geotechnical perspective, the proposed development,
as it involves obviously steep land, can be undertaken so as to be safe to persons and
property.
[13] For the appellants, reliance is placed upon the joint expert report of the geotechnical
experts, in which agreement is expressed to the effect that by employing specified
mitigation measures, to all of which the appellants have expressed agreement, the
proposed development can be undertaken so that the level of risk is reduced to low or
very low.
[14] The appellants have also indicated their preparedness to consent to conditions
required by the co-respondent, except for a requirement for a 10 metre wide easement
for the water main that traverses the land.9 Accordingly the dispute between the
appellants and co-respondent is so limited. The appellants’ contention is that the
relevant applicable codes only support the imposition of a 3 metre easement and that
they have offered 6 metres as being more than sufficient to provide access for
equipment and vehicles. As is pointed out by the appellants, s 345 of SPA provides
as follows in respect of the imposition of conditions, as part of any approval:
“345 Conditions must be relevant or reasonable
(1) A condition must—
(a) be relevant to, but not an unreasonable imposition on,
the development or use of premises as a consequence
of the development; or
(b) be reasonably required in relation to the development
or use of premises as a consequence of the
development.
(2) Subsection (1) applies despite the laws that are administered
by, and the policies that are reasonably identifiable as policies
applied by, an assessment manager or concurrence agency.”
The appellants’ contention is that a condition for a 10 metre easement is an
unreasonable imposition.
8 Ex. 1, vol. 1, p 6.
9 Ex. 1, vol. 1, pp 37-9.
-- 6 of 38 --
7
[15] It is the respondent’s position that in the event that this application is approved, there
are additional conditions that would be required. The appellants made clear in
opening their case to the Court, that they would consent to the specific conditions
which had been identified prior to the hearing by the respondent, as being necessary
in the event that the application was approved.10 Those conditions generally related
to the traffic and geotechnical requirements that had been identified by the retained
experts in each discipline.
[16] It is nevertheless the respondent’s position that, having regard to town planning
issues, the application should be refused. In particular, it is the respondent’s position
that the application is in substantial conflict with the Maroochy Plan 2000 and also
the Sunshine Coast Planning Scheme 2014, and that having regard to the inherent
characteristics of the land, including:
(a) The likelihood of “failure” or landslide occurring during the design
life of the proposed development; and
(b) The need for additional works in the nature of removal of landslide
debris following each such event, in order to maintain a consistent risk
profile during the life of the development;
there are insufficient grounds to justify an approval despite such conflict.
The construction of planning schemes
[17] In the first instance it should be noted that the proper construction of a planning
scheme is a question of law and a matter for the court, rather than any particular
evidence that may be given in respect of such schemes.11 It is particularly recognised
that planning schemes should be construed broadly, rather than pedantically or
narrowly and with a sensible, practical approach.12
[18] A useful summary of the by then established principles to be applied in this context,
is to be found in Westfield Management Ltd v Pine Rivers Shire Council:13
10 Ex. 1, vol. 1, pp 31-2 (as they were corrected during the hearing).
11 See HA Bachrach Pty Ltd v Caboolture Shire Council (1992) 80 LGERA 230, as applied in Yu Feng
Pty Ltd v Maroochy Shire Council (1996) 92 LGERA 41, at 59 per Fitzgerald P.
12 Degee & Anor v Brisbane City Council & Anor [1998] QPELR 287, ZW Pty Ltd v Peter R Hughes &
Partners Pty Ltd [1992] 1 Qd R 352 at 360, Yu Feng Pty Ltd v Maroochy Shire Council (1996) 92
LGERA 41, at 73,75 and 78 and Harburg Investments Pty Ltd v Brisbane City Council [2000]
QPELR 313, at 318.
13 [2004] QPELR 337, at 342.
-- 7 of 38 --
8
“(a) they should be construed broadly rather than pedantically or
narrowly and with a sensible, practical approach (ZW Pty Ltd
v Peter R Hughes & Partners Pty Ltd [1992] 1 Qd R 352 at
360; Yu Feng Pty Ltd v Maroochy Shire Council (1996) 92
LGERA 41, at 73,75, 78; Harburg Investments Pty Ltd v
Brisbane City Council [2000] QPELR 313 at 318.
(b) they should be construed as a whole (Luke v Maroochy Shire
Council & Anor [2003] QPELR 447);
(c) they should be construed in a way which best achieves their
apparent purpose and objects (Luke v Maroochy Shire Council
& Anor (supra); Nordale Management Pty Ltd v Maroochy
Shire Council [1995] QPELR 368 at 370; Acts Interpretation
Act 1954 s. 14A);
(d) in the light of the proscription against prohibiting development
contained in IPA (s. 6.1.2(3));
(e) Statements of Intents or Aims or Objectives are intended to
provide guidance for the task of balancing the relevant facts,
circumstances and competing interests in order to decide
whether a particular use should be rejected as inappropriate
(Degee v Brisbane City Council [1998] QPELR 287);
(f) a Strategic Plan sets out broad desired objectives and not every
objective needs to be met before a proposal can be approved
(Lewiac Pty Ltd v Gold Coast City Council (1994) 83 LGERA
224 at 230);
(g) a Strategic Plan should be read broadly and not pedantically
(Yu Feng Pty Ltd v Maroochy Shire Council (supra));
(h) although planning documents have the force of law they are
not drawn with the precision of an Act of Parliament;
(i) a conflict alone may not have the effect of ruling out a
particular proposal (Fitzgibbons Hotels Pty Ltd v Logan City
Council [1997] QPELR 208 at 212);
(j) implementation objectives must be read sensibly and in
context. They are but a function of the principle objective.
The purpose of the objective is better understood by reading
all of the implementation objectives and understanding the
strategy that is inherent (Jenkinson Pty Ltd v Caloundra City
Council [2002] QPELR 527 at 528).”
[19] Some more practical guidance to the task of construing the planning schemes are to
be found in:
(a) the observations of Robin QC DCJ in Vynotas Pty Ltd v BCC:14
“In a complex appeal such as this, the court should read the
planning scheme as a whole. I have set out extensively
passages which I accept are relevant, and have taken into
14 [2001] QPELR 14 at 40.
-- 8 of 38 --
9
account. The scheme is bulky, often repetitive, and not
devoid of conflicting messages. Provisions are there which
come close to providing ‘support for almost any argument’,
to quote Senior Judge Skoien in Drivetype Pty Ltd v Council
of the Shire of Caboolture …”;
(b) the observations of Skoien SJ DC in Drivetype Pty Ltd v Caboolture
Shire Council:15
“I am attracted to the planning approach of the Shire’s
planning officer… which is to emphasise the necessity of
reading the strategic plan as a whole. That is not to say that
one goes in search of an isolated statement anywhere in the
document which, when taken out of context, might support an
argument. Such a search, in most planning schemes, could
unearth support for almost any argument. If however a
statement can be found which clearly sets out a fundamental
principle of the Planning Scheme which argues for or against
a proposal, then it is proper to give weight to it even though
the proposal relates to land which is specifically dealt with in
another part of the document.”; and
(c) in the observations of Wilson SC DCJ in Luke & Ors v Maroochy
Shire Council and Watpac Developments Pty Ltd:16
“the plan is a dramatic example of the growth in the size and
complexity of planning schemes in recent times. Inevitably,
the expansion of these planning documents will generate
internal tensions or inconsistencies and, occasionally,
different passages in them will appear to express a desire for
what seemed to be competing objectives. That prospect
compounds the necessity for a careful and balanced, but not
unduly pedantic, approach to the interpretation of their
provisions.
….
The undeniable purpose of a town planning scheme is to
regulate, within reasonable limits consonant with the personal
liberties of landowners, the provision and distribution of
appropriate community facilities, both private and public,
with a view to promoting the general wellbeing of the
occupants of the relevant local government area. The
approach to construction of Maroochy Plan 2000 advanced
by the respondent seems to me to accord with that discussed
in the authorities I have reviewed and, in this instance, with
the approach taken by Robin QC, DCJ and very similar
circumstances in Tallenbrook, which places weight upon the
purposive elements of the scheme, with its emphasis on
community need as an important aspect of town planning, and
15 [1995] QPLR 141 at 143.
16 [2003] QPELR 447.
-- 9 of 38 --
10
gives no special weight to what might be called, here, the
“microcosmic” aspects of the plan touching, at its lowest
levels, individual communities.
This does not mean that the structure of this plan with, as the
Appellants correctly point out, its apparent descent from the
general to the particular is inappropriate but, rather (to use the
Appellant’s own metaphor) that what is found at its most
detailed levels is not, necessarily, gold – but neither, of
course, is it dross. If, as here, the Planning Scheme at it most
particular level suggests the proposed development might not
be in harmony with what appears to be generally intended for
a precinct, that cannot and does not mean that the proposal
automatically fails. Rather, the planning authority and if
necessary the Court, considers all the relevant elements of the
plan, including those matters to which the scheme itself pays
significant obeisance: community need, and demand; the
desirability of, and possible benefits from, the proposal; the
impact it would have; and, of course, the prevailing realities
– whether development in the area has advanced, or will
advance, in accordance with the plan.”
[20] Further and in the implementation of such a holistic approach and in determining
pursuant to s. 326 of SPA whether there is conflict, any such conflict must be plainly
identified.17 However and should conflict be plainly identified, the legislative
requirement is that the application be refused unless, grounds are identified which
justifies a decision to approve it.18 The sufficiency of justifying grounds must be
determined by having regard to both the nature and extent of the identified conflict.19
Significant aspects of the evidence
[21] It was common ground that for the application of the Maroochy Plan 2000, the land
is situated in “Precinct 4 – the Buderim Scarp Landscape Conservation Precinct”.
[22] The proposed subdivision of the land is visually depicted on the aerial photograph at
p 156 of Exhibit 1 and schematically, in the plan at p 464A of Exhibit 1. Four lots,
to be numbered 10 through 13, are proposed. Lot 10 is to encompass 246m² of the
land and upon which the existing residence is situated. This is to comprise the
generally higher elevated portion of the land, which adjoins Jones Road and which
abuts Lot 9 (the site of the Unitywater Pump Station) in the southerly aspect and
17 Fitzgibbons Hotel Pty Ltd and Ors v Logan City Council & Anor [1997] QPELR 208
18 s. 326(1)(b)
19 Weightman v Gold Coast City Council [2003] 2 Qd R 441, at 453 and Woolworths Ltd v
Maryborough City Council & Anor [2006] 1 Qd R 273, at [23] and [25].
-- 10 of 38 --
11
extends up to the intersection with Lindsay Road, in the northerly aspect. The
proposed Lots 11 to 13, will comprise both the lowest parts of the land and also the
steepest slopes and will provide for three new building envelopes, generally on the
lower part of the land. This will be in separate lots, respectively sized 2005m²,
2005m² and 2001m².
[23] Although and in the “Regulatory Map – Landslip Hazard”,20the land is included in
the “Moderate Landslip Hazard” category, in the “Regulatory Map – Steep Land”,21
the land is designated in the category of slopes of 20% and over. In the Golder and
Associates report on slope stability assessment, dated June 2014, the following
description of the topography of the Land, is provided:
The site is located on the lower slopes in the north western section of
the Buderim escarpment. The ground surface generally falls to the
west, with distinct terraces aligned in a north-south orientation across
the site. Grounds slopes in the upper portion (eastern) of the site were
typically in the range of 23° to 32°. The slope flattens in the lower
portion (western) of the site typically in the range of 5° to 18°. Slope
angles were measured in the field using a hand held inclinometer and
are noted in Figure 1. Ground surface contours are shown in Figure 2
attached. The contour survey was undertaken in 2011 and some
earthworks have been carried out and retaining walls constructed since
then. However, the contour survey information is considered generally
representative of the existing site conditions across proposed Lots 12
and 13.22
By reference to Exhibit 2 and in order to correlate the references to degrees of slope,
to the expression of grade or gradient, in percentage terms (as in the Planning
Scheme), it should be understood that a slope of 14° correlates to a grade of 25%, a
slope of 22° to a grade of 40%, a slope of 26° to a grade of 50% and a slope of 30° to
a grade of 57%. Accordingly, it may be seen that the land includes, to a significant
extent, slopes that substantially exceed the 20 % and 25% yardsticks, which assume
significance in consideration of the planning scheme.
[24] For the appellant, particular emphasis was placed upon the agreement reached in the
joint reports of the geotechnical experts (“GTJER”) as to mitigation measures or risk
mitigation strategies that should be implemented to appropriately alleviate
unacceptable risk to person and property, having regard to the potential for landslip
20 Ex 1, vol. 2, at p 453.
21 Ex 1, vol. 2, at p 454.
22 Ex 1, at p 138 and see Figure 1, at p 152 and Figure 2, at p 153.
-- 11 of 38 --
12
on the site in general, the consequences of failure, the potential for instability to affect
Jones Road, the potential for instability to affect the existing Unitywater Pump
Station, the potential for construction of sewerage infrastructure to affect land
stability and risk management strategies generally.23 In particular, emphasis is placed
upon the following agreed position, as stated in the GTJER:24
“3.7 Risk management strategies
3.7.1 General
The experts are agreed that:
The risk associated with the developments of Lots 12 and 13 is
‘Moderate’. Phillip Shaw is of the opinion that this could
increase to ‘High’ depending on the cost involved in remedial
work. Any risk mitigation strategy needs to take into account
the potential for instability of the southern slopes of Lot 10 and
their effect on Lot 12.
Slope instability issues on Lot 11 relate largely to the potential
instability of man-made features primarily the terracing and
boulder walls which have been constructed up-slope of the
proposed building envelope.
The risk of development on Lots 11, 12 and 13 needs to be
reduced to ‘Very Low’ to ‘Low’.
The recommendations in sections 8.0 and 9.0 of the Golder Associates
report should be implemented so that an acceptable risk rating is
achieved for each of the proposed building envelopes. The following
sections highlight some of the specific discussions between Geoff
Hurley and Phillip Shaw.
3.7.2 Lots 12 and 13
The experts are agreed that it is not possible to economically stabilise
the steep slopes and the potential for instability of the slopes remains.
Risk mitigation strategies on Lots 12 and 13 are aimed at protecting
any houses on the building envelopes from consequences of failures
on the slopes above.
The experts agree that the risk of development can be reduced to ‘Low’
by implementing the following measures:-
The construction of a catch berm or catch barrier as shown
schematically in Section 8.2 of the Golder Associates report.
The protective measures should be designed by a suitably
23 Such risk was assessed by reference to the Australia Geomechanic Society (AGS) Guidelines for
Landslide Risk Management (March 2007).
24 Ex. 1, vol. 1, at pp 124-125.
-- 12 of 38 --
13
qualified and experienced Geotechnical Engineer. The catch
berm is only suitable where the proposed houses are constructed
on an elevated fill platform. This mitigation strategy will
address consequences of slope instability on Lot 12, Lot 13 and
from Lot 10.
Any existing uncontrolled fill including the stockpile on Lot 12
should be removed or stabilised.
The existing unsupported cuts on Lot 12 should be stabilised.
Any existing unsupported cuts above 1m in height should be
retained by engineer designed retaining structures.
A retaining wall should be constructed on the upper slopes of
Lot 12 and Lot 13 to protect the pump station site from the
potential up-slope migration of instability. The retaining wall
should be founded within weathered rock to provide an effective
cut off against instability.
3.7.3 Lots 10 and 11
With the exception of the natural slopes to the south of the existing
house on Lot 10, the potential for instability on Lots 10 and 11 related
primarily to man-made structures. Lot 10 is included due to the
potential for instability originating on this allotment to affect Lots 11
and 12. On the basis of observations to date it appears likely that
further earthworks will be carried out on Lot 11.
The experts agree that the following process be implemented for the
development of Lots 10 and 11:-
Flatten all slopes to no steeper than 1V:2H (27 degrees).
All earthworks to be constructed in accordance with the
recommendations of the Golder Associates report.
Assess the stability of all cut and fill batters and remediate where
required.
Check the local and global stability of all existing terraces and
boulder walls (above 1m in height) and obtain certification from
a suitably qualified and experienced Registered Professional
Geotechnical Engineer (RPEQ).
Investigate the foundation conditions within the building
envelope and provide site specific footings design
recommendations to address the presence of uncontrolled fill.
This is standard practise and can be undertaken once earthworks
and the house design are complete.”
[25] As the respondent correctly points out, the particular focus as to the reduction of risk
level, in this geotechnical sense, is clearly directed at the building envelopes for the
proposed building development on the lower aspect of the land. Otherwise, and as
-- 13 of 38 --
14
the following extract of the summary of the GTJER exemplifies, the risk of landslide,
and therefore in respect of the Land more generally, was to remain unmitigated:
“3.9 Summary
In summary the experts agree:
The proposed building envelopes can be developed with a
suitably low risk of instability to property, subject to the
recommendations provided in this report.
The potential for instability of the steeper slopes outside the
building envelopes on Lots 10, 12 and 13 remains unmitigated.
The risk of instability on Lot 10 affecting the road pavement (i.e.
extending beyond the kerb and channel) on Jones Road is ‘Very
Low’.
The Unity pump station site can be protected from the effects of
instability on Lots 12 and 13 by the construction of a retaining
wall founded within weathered rock on the upper slopes of Lots
12 and 13.”25
The planning documents
[26] Pursuant to s 314 and s 495(2) of SPA and in the context of this case, the relevant
planning documents are:
(a) The South East Queensland Regional Plan 2009-2031;
(b) The State Planning Policy 1/03 – Mitigating the Adverse Impacts of
Flood, Bushfire and Landslide (Bushfire and Landslide);
(c) The Maroochy Plan 2000; and
(d) The Sunshine Coast Plan 2014.
[27] The South East Queensland Regional Plan was introduced on 28 July 2009 and in it,
the subject land is located in the “Urban Footprint”. There is no suggestion that the
proposal is inconsistent with the regional land use intent or regional policies or the
desired regional outcomes for this land use designation.
[28] The State Planning Policy 1/03 was in force at the time the application was made.
However it is acknowledged26 that this State Planning Policy has been appropriately
reflected in the Maroochy Plan 2000 and as much was conceded by the respondent.27
Subsequently to the institution of this appeal, the State Planning Policy 2014 was
25 Ex. 1, vol. 1, at p 126.
26 Town planning joint expert report (“TPJER”), at 6.3.2: Ex. 1 Vol. 1, at p 235.
27 Ex. 1, vol. 1, at p 18.
-- 14 of 38 --
15
introduced. However, the Sunshine Coast Plan 2014 expressly acknowledges that the
State Planning Policy 2014 is appropriately reflected within it28 and there is no
suggestion raised otherwise.
[29] Accordingly and as was the focus of the submissions of the parties, it is necessary to
examine any conflict with the Maroochy Plan 2000 and to the extent that weight may
be given to it, the Sunshine Coast Plan 2014.
Is there conflict with the provisions of the Maroochy Plan 2000?
[30] The approach for the appellant is to point particularly to the geotechnical evidence
and the agreement of the experts expressed at 3.8 of the GTJER that the identified
risk mitigation measures, if adopted, would reduce the risk to persons and property
from the potentiality of landslides to very low to low, with the further comment that
“such a risk rating is normally acceptable to regulators”. It may be observed that that
comment is of little assistance. First and as correctly identified by the town planning
experts, in the town planning joint expert report (“TPJER”) at 6.4.2, there are, in
addition, town planning implications to be considered, which may be informed (but
not necessarily determined) by the opinions, best expressed by the geotechnical
experts and relating to the stability of the site and the potential for landslide hazard.
[31] As the respondent emphasises, the first critical question for the court is to determine
whether there is conflict with the Maroochy Plan 2000. The emphasis that the
appellant seeks to place on the geotechnical evidence in this regard, is summarised in
the following submission:
“91. In light of the state of the geotechnical evidence, it is apparent
that the development as proposed can maintain the safety of
people and property from the risk of landslide. As a result it is
difficult to see how the Council can maintain that the proposed
development is in conflict with the provisions of the Maroochy
Plan.”29
[32] However, that contention should not be accepted and upon a holistic assessment of
this planning scheme, it is clear that there is substantial conflict. As contended by the
respondent,30 it may be accepted that a broad consideration of the plan reveals a three
28 Ex. 1, vol. 2, at p 385.
29 See appellant’s written submissions at p 24 [91].
30 Respondents written submissions, at [38].
-- 15 of 38 --
16
limbed planning approach, or strategy, with respect to the development of steep and
potentially unstable land, as the subject land is:
(a) First and while accommodating the residential use of existing lots, by
actively discouraging the creation of additional lots in the precincts or
zones in which the subject land is found in the scheme;
(b) Secondly and in any event, discouraging any development on land
with slopes greater than 25%; and
(c) Thirdly, ensuring that any form of development, which could include
other forms of development, 31 is compatible with the hazard presented
by the steep and unstable land and does increase the risk of harm to
people or property.
[33] Further and as the respondent also correctly contends, whilst the evidence of the
technical engineers is directed at the third limb of this planning strategy, it does not
directly address the other limbs.
[34] The conflict with the Maroochy Plan 2000 is to be particularly discerned by reference
to the following provisions:
(a) In “Volume 2 Strategic Plan”:
(i) Under the heading “3 Urban Development” and the
subheading “3.5 Objectives and Implementation Measures”,
the following statements appears:
“3.5.4 To Ensure that the Physical Environment can
Sustain Urban and Rural Residential Development
Because the shire’s urban areas comprise significant
areas of steep or slip-prone land, potential exists for
inadequate drainage, slope retention and site planning to
compromise the conditions of development below and to
scar visually prominent features of the landscape.
Substantial amounts of land are also flood-prone.
Implementation criteria are intended to ensure sound
planning prevents or minimises potential problems.
…
Implementation
…
4. All applications are to address the possibility of
impacts relating to steep or slip-prone land in accordance
with the provisions of s 18.0 of the Strategic Plan and
relevant planning scheme codes.
31 See the definition of “development” in ss 1 and 10 of SPA.
-- 16 of 38 --
17
…”32
(ii) Under the heading “18. Slope and Geological Stability”:
“18.1 Explanation
‘Slope’ refers to the inclination of topography or altered
made grade (refer to the Administrative definitions in
Volume 1 of the planning Scheme). ‘Geological
stability’ refers to the particular interaction of soil,
underlying rock, ground water and slope on the stability
of any site.
18.2 Key Issues
The key issues dictating the planning strategy for steep
and geologically unstable land include:
the impact of clearing and grazing on steep or
unstable land leading to sheet or gully erosion,
hillside creep, slumping or debris flows;
in urban areas, conventional residential
development on steep or unstable lands requiring
overly steep batters, retaining walls and fill which
may result in structural failure, soil erosion and
drainage issues with adjoining land owners;
…
18.3 Slope and Geological Stability Strategy
The following outlines the elements of the planning
strategy to be employed for the development of steep and
geologically unstable land.
…
18.3.1
…
The Slope and Geological Stability Strategy requires
matching the range of land uses to the difficulties
imposed by the topography of the land, by requiring,
where there is an area of known geological instability,
such information as is necessary to determine the
suitability of the site for the proposed development and
by imposing such conditions as are necessary to minimise
the potential for soil erosion and land slip.
…
18.4 Objectives and Implementation Measures
18.4.1 To Encourage Activities Appropriate to the
Slope of the Land
…
In urban areas, recognition is given to the limitations of
slope, particularly in multi-unit density, lot size and
dimensions. This has important implications for the
standards and Performance Criteria adopted for the
reconfiguration of land and forms a design of urban
development in such areas.
…
Implementation
32 Ex. 1, vol. 2, at pp 267-8.
-- 17 of 38 --
18
1. When assessing development applications, council
will give preference to proposals which recognise the
natural characteristics of a site.
…
2. In assessing a proposal on land classified on regulatory
map 1.1 (1 of 2) Landslip Hazard as being of moderate,
high or very high hazard, or classified as low or very low
but with slopes of 15% or greater in areas A to H or
classified as low or very low but with slopes of 20% or
greater in other areas, due regard shall be given to:
the probability of soil erosion and landslip;
the potential for structural failure;
the likely impact of drainage on adjoining
properties;
the extent of earthworks;
the likely impact of vegetation removal on
stability;
the impact on permanent and intermittent water
courses; and
the potential for visual scarring.
…
4. Council has prepared a code for the assessment and
management of land on steep and unstable land to ensure
the key issues outlined in 18.2 are adequately addressed.
5. If after assessing any proposal on steep land, council is
not satisfied that the development can be appropriately
managed, it may not support the application.
…
18.4.2 To Ensure That Due Regard is Given to the
Constraints of Likely Geological Instability
There are areas of known geological instability within the
shire.
Implementation
1. Geotechnical report will be requested for development
applications where land is affected by land prone to
slippage, as determined by the regulatory maps included
in this Planning Scheme.
…
4. If after assessing any proposal on land prone to
slippage, council is not satisfied the land can be
appropriately managed, it may not support the
application.”33
(b) It is common ground that the subject land is situated in “precinct 4
Buderim Scarp Landscape Conservation Precinct”, which is a
“Hillslope Residential Precinct”. For such a precinct and in “Volume
3, Planning Areas, Precincts and Precincts Classes” and which is
33 Ex. 1, vol. 2, at pp 273-4.
-- 18 of 38 --
19
stated to “contain the statements of intent and desired character” for
each such area, precinct or class:
(i) The following appears under the heading “2.2 General Intent
for Residential Precincts”:
“(1) Hillslope Residential
These precincts provide for mainly detached houses in
urban areas with land generally having slopes greater
than 15% (about 1 in 6). However, the development of
land with slopes greater than 25% (1 in 4) is generally
considered inconsistent with council’s planning intent for
the shire.”;34
(ii) Under the subheading “3. Statements of Desired Character for
Planning Areas and Precincts” and the further subheading “3.6
Planning Area No 6 – Buderim” and “3.6.4 Statements of
Desired Character”, the following appears:
“(4) Buderim Scarp Landscape Conservation
(Precinct Class = Hillslope Residential)
Intent
This Precinct comprises predominantly steep and sloping
land that supports extensive remnant vegetation and
wildlife habitats. These intensely green, vegetated slopes
are of very high conservation, habitat and amenity value.
Their character and prominence in the district’s landscape
are fundamental to the character and identity of Buderim
as well as the Shire and this part of the Sunshine Coast.
The landscape of the Precinct provides a dramatic contrast
to the urban development that has occurred on the
Buderim Mountain plateau, on other parts of the Scarp and
along the coastal urban strip.
It is intended that future development in this Precinct
conserve and enhance the significant environmental and
landscape values and character of the remnant bushland on
the Buderim Scarp.
Much land in this Precinct is not considered suitable for
urban development due to its environmental and landscape
values, and constraints associated with the difficulties of
providing safe, convenient and economical access to
services.
…
Preferred and Acceptable Uses
Preferred uses within this Precinct are those referred to in
the Table of Development Assessment (refer Vol 1) for the
Hillslope Residential Precinct, mainly detached houses on
existing lots and where the landscape and environmental
values of the area can be protected.
34 Ex. 1, vol. 2, at p 281.
-- 19 of 38 --
20
Landscape and Built Form
Any development should be located and designed such
that it has minimal impact on the landscape. Development
should be sited and designed to avoid destruction of
mature vegetation and habitats, erosion and extensive
earthworks. … Clearing of native vegetation should be
minimised other than for previously approved sites for
dwellings and ancillary buildings, access and necessary
infrastructure.
…
Preferred Maximum Density
One dwelling per lot as existing on the
commencement day….”35
[35] Further and as to the development codes that are provided in this scheme, the
following may be noted:
(a) “2. GENERAL LAND USE AND DEVELOPMENT CODES”:
“2.1.4 Code for Development on Steep or Unstable Land
PURPOSE
The purpose of this code is to achieve the following outcomes:
(a) Development on steep or unstable land is compatible with the
nature of the hazard and with the environmental and visual
characteristics of the site and surrounding land;
(b) Development maintains the safety of people and property from
the risk of landslide;
(c) Development on slopes of more than 25% occurs only where
the scenic and environmental quality of the locality is
maintained.
(1) Element: Unstable Land
PERFORMANCE CRITERIA / ACCEPTABLE MEASURES
P1 Development does not increase the
risk of harm to people or property or
reduce the safety of hazardous materials
manufactured or stored in bulk as a
result of landslide. Mitigation works are
provided in a manner which minimises
whole of life cycle costs.
A1.1
The development does not:
involve new building work which
exceeds 20m2 gross floor area that
involves additional footings or
structural slab on ground; or
involve vegetation clearing; or
alter ground levels to an extent that
involves the excavation or filling of
more than 50m3 of material (other
than the placement
of topsoil not exceeding 100mm in
depth); or
35 Ex. 1, vol. 2, at pp 298-9.
-- 20 of 38 --
21
create cuttings or fillings with a
vertical depth greater than 1.5 metres
relative to ground level; or
re-direct or impede water flows in
existing water courses, ground water
or storm water drains (whether natural
or manmade); or
require the construction of new
stormwater drainage to service new
impermeable surface areas (including
roofed areas) exceeding 50m2; or
involve the construction of an on-site
sewerage facility.
Or
An appropriately qualified professional
carries out sufficient investigation work
and certifies that the stability of the site
will be maintained during the course of,
and following the development, and that
the site is not subject to risk of landslide
activity originating from other land. This is
in accordance with Planning Scheme
Policy No. 4 –Preparation of Geotechnical
Reports.
”
(b) “8. CODE FOR CONFIGURING LOTS:
The purpose of this code is to achieve the following outcomes:
(a) Lot reconfiguration facilitates the creation of safe,
convenient, functionally efficient and attractive environments, which
are consistent with the desired character of the precinct in which the
development site is situated;
…..
(c) Lot reconfiguration is responsive to the local environment,
including its topography, natural drainage systems, vegetation and
habitat, cultural heritage features, streetscape character, landmarks,
views and vistas;
(d) Development on steep or unstable land is compatible with the
nature of the hazard and with the environmental and visual
characteristics of the site and surrounding land, and maintains the
safety of people and property from the risk of landslide;
(e) Development on slopes of more than 25% occurs only where
the scenic and environmental quality of the locality is maintained.”36
…..
36 Ex. 1, vol. 2, at p 330.
-- 21 of 38 --
22
2. Lot Size and Dimensions:
PERFORMANCE CRITERIA ACCEPTABLE MEASURES
P1 Lot size and dimensions:
(a) are consistent with the desired
character of the precinct in
which the lot is situated;
(b) respond to the environmental
qualities of the site, including
scenic topographic, natural
or cultural features;
(c) are consistent with the
physical capabilities of the
land, having particular regard
to its slope and stability;
(d) minimise the need for earthworks
(e) minimise the need for
vegetation loss;
(f) enable the provision of:
(i) buildings and set backs;
(ii) private open space
and buffering;
(iii) convenient vehicle access
and on site parking; and
(iv) necessary on-site services;
that are appropriate to
the proposed or expected
use of the land;
(g) facilitate climate responsive
design which conserves the use of
non renewable energy sources;
(h) ensure, in rural precincts:
(i) good quality agricultural
land is conserved and the
productive capacity of this
and other rural land resources
is maintained; and
(ii) the spacing of home sites
as far apart as practicable
along road frontages.
A1.1
(a) Lot size and dimensions are consistent
with Table 8.2; or
(b) In a Rural Precinct (other than within a
Water Resource
Catchment area as shown on Regulatory
Map 1.614), lots with
an area and dimensions less than that
nominated in Table 8.2 are
only created where:
(1) (i) there exists a development permit
for a material change of
use for a rural service industry or intensive
animal husbandry
which will be fully contained within the
proposed lot; and
(ii) the lot is used only for the purpose of a
rural service industry
or intensive animal husbandry and no
residential premises
(apart from a Caretakers residence) is
established; and
(iii) the lot area and dimensions enable the
approved use of the
land to comply with the requirements
(including buffers)
outlined in the relevant codes applicable to
the particular use.
OR
(2) (i) the lots result from a realignment of
lot boundaries to reduce
the area of one or more lots in order to
create a larger lot
over the balance area; and
(ii) there is no increase in lot yield or
potential to increase lot
yield as a result of the farm restructuring;
and
(iii) each of the smaller lots created
contains a habitable detached
house; and
(iv) each of the smaller lots has an area of
not less than 4000m2;
and
(v) it does not fetter the existing or
potential productivity of the
site, surrounding rural land or adjoining
rural industries;
AND
A1.2 No additional lot is created with a
slope of 25% or greater.
AND
A1.3 No additional lot is created within a
Rural Precinct in a Water
Resource Catchment Area as shown on
Regulatory Map 1.6.
-- 22 of 38 --
23
Is there conflict with the 2014 scheme?
[36] As has been noted, s 495(2)(a) of SPA allows for appropriate weight to be given to
the Sunshine Coast Plan 2014, which came into effect on 21 May 2015 and therefore
subsequently to lodgement of both the development application and therefore this
appeal.
[37] Before considering what, if any, weight might be appropriately given to this present
scheme, it is necessary to consider whether or not the proposed scheme is in conflict
with it. In this instance, the appellant concedes that there is conflict.
[38] First, this is because of an overall outcome seeking that development does not result
in the creation of additional lots. As stated in the “Limited development (landscape
residential) zone code”, at 6.2.18.2(2)(d) and which appears in some immediate
context, as follows:
“6.2.18.2 Purpose and overall outcomes
(1) The purpose of the Limited development (landscape
residential) zone code is to ensure land which is located in an
urban or rural residential setting but which has been
determined to be unsuitable for urban purposes due to the
presence of one or more of the following constraints:-
(a) flooding;
(b) ecologically important areas;
(c) steep land or landslide hazard;
(d) access limitations; and
(e) an amenity deficiency caused by proximity to a major
transport corridor or facility;
is appropriately developed having regard to the constraints of
the site. Such constraints pose severe restrictions on the ability
of the land to be developed for urban or rural residential
purposes.
(2) The purpose of the Limited development (landscape
residential) zone will be achieved through the following
overall outcomes:-
…
(b) dwelling houses may be established in the zone only
where a suitable building site can be identified which
maintains the safety of people, buildings and works,
having regard to the physical constraints of the land;
-- 23 of 38 --
24
…
(d) development does not result in the creation of any
additional lots to those existing at the commencement
of the planning scheme;
(e) development is designed and sited to sensitively
respond to the physical characteristics and constraints
of land, including flooding, steep land, landslide
hazard and bushfire hazard, where applicable;
…”37
[39] Secondly and because the land lies immediately outside the immediate urban growth
boundary, as marked by the blue line depicted on the 2014 planning scheme Buderim
local plan, at p 9 of Exhibit 1 and referred to in Exhibit 4, the report of
Mr Schomburgk, at [22] and the attached zone map, and due to the overall outcome
stated in relation to the “Buderim local plan code”, at 7.2.5.3(2)(b), in terms that:
“7.2.5.3 Purpose and overall outcomes
(1) The purpose of the Buderim local plan code is to provide
locally relevant planning provisions for the assessment of
development within the Buderim local plan area.
(2) The purpose of the Buderim local plan code will be achieved
through the following overall outcomes:-
…
(b) Urban and rural residential development within the
Buderim local plan area is limited to land within the
urban and rural residential growth management
boundaries respectively so as to protect the
undeveloped parts of the Buderim escarpment, avoid
land otherwise substantially constrained to
development and provide for the efficient provision of
infrastructure and services.
…”
[40] However and whilst those provisions may evince conflict with the 2014 scheme, the
extent of the conflict does not rest there. As contended by the respondent, it may be
discerned that the same threefold planning strategy adopted in the 2000 scheme has
been maintained, if not in some respects strengthened.
37 Ex. 1, vol. 2, at p 398.
-- 24 of 38 --
25
[41] Any assessment of the Sunshine Coast Planning Scheme 2014 must necessarily have
regard to the following stated hierarchical structure:
“1.5 Hierarchy of assessment criteria
(1) Where there is inconsistency between provisions within the
planning scheme, the following rules apply:-
(a) the strategic framework prevails over all other
elements to the extent of the inconsistency;
(b) statewide codes prevail over all other elements
(other than the strategic framework) to the extent of
the inconsistency;
(c) overlays prevail over all other elements (other than
the strategic framework and statewide codes) to the
extent of the inconsistency;
(d) local plan codes prevail over zone codes, use codes
and other development codes to the extent of the
inconsistency;
(e) zone codes prevail over use codes and other
development codes to the extent of the
inconsistency;
(f) provisions of Part 10 (Other plans) may override
any of the above.”38
[42] Part 3 of the 2014 scheme contains the strategic framework and, therefore, the highest
order provisions. These relevantly include:
(a) As a “Key concept” under the heading “3.3 Settlement Pattern”:
“(2) Urban and rural residential development that is contained
within defined local growth management boundaries.”;39
(b) The following, under the heading “3.3.1 Strategic Outcomes”:
“The strategic outcomes for the settlement pattern theme are the
following:-
…
(b) Growth is contained within defined local growth management
boundaries that apply and refine the land use categories in the
SEQ Regional Plan. These local growth management
38 Ex. 1, vol. 2, at p 382.
39 Ex. 1, vol. 2, at p 386.
-- 25 of 38 --
26
boundaries reflect the outcomes of detailed local
investigations.
(c) Urban development and rural residential development is
contained within local growth management boundaries so as
to protect biophysical and landscape values and natural
resources, avoid natural hazards, maintain the individuality of
communities and provide for the efficient delivery of
infrastructure and services.”40
(c) Under the heading “3.3.3 Element 2 – Growth management boundaries
and land use categories”:
“3.3.3.1 Specific outcomes
(a) Local growth management boundaries and land use
categories are identified for the region.
(b) Urban development is limited to land within the urban growth
management boundary identified conceptually on Strategic
Framework Map SFM 1 (Land use elements) and in further
detail on the zoning maps.
…
(d) The physical extent of urban development and rural
residential development is contained within defined local
growth management boundaries so as to:-
…
(iii) avoid natural hazards, including an allowance for the
predicted impacts of climate change that may worsen
these hazards;
…
(e) The pattern, form and structure of settlement are consistent
with the land use categories identified conceptually on
Strategic Framework Map SFM 1 (Land use elements).
These land use categories comprise urban areas, rural
residential areas, rural enterprise and landscape areas, major
sport and recreation open space and major conservation
areas.”;41 and
(d) As “Key concepts” under the heading “3.10 Natural hazards”:
“(3) Achievement of an increased level of resilience to natural
hazards such that natural hazards do not pose a serious risk to
40 Ibid.
41 Ex. 1, vol. 2, at p 388.
-- 26 of 38 --
27
people, property, community health and wellbeing, economic
activity and the region’s biophysical values.
(4) Adoption of a precautionary and conservative approach to
planning for natural hazards.
(5) Adoption of mitigation measures that are compatible with the
nature of each natural hazard taking account of its predicted
frequency and severity.
(6) Reshaping the pattern of settlement to avoid development in
areas subject to the critical natural hazards of bushfire, coastal
erosion, flooding and landslide.
…
3.10.1 Strategic outcomes
The strategic outcomes for the natural hazards theme are the
following:-
…
(c) Hazard avoidance and management strategies reflect a
precautionary and conservative approach that recognises the
high risk profile of the Sunshine Coast as an area where a
significant proportion of development is located adjacent to
the coast and in river plains.
(d) The pattern of settlement is shaped such that new urban areas
are not affected by critical natural hazards and in particular,
are not potentially at risk from bushfire, coastal erosion,
flooding and landslide.
(e) Where natural hazards cannot practically be avoided,
appropriate adaptation responses are adopted to reduce the
risk and severity of the impact of the hazard.”;42 and
“3.10.6 Element 5 – Landslide and steep land
3.10.6.1 Specific outcomes
(a) The risk of harm to people, property, economic activity and
the environment due to landslide is minimised.
(b) The use of areas and the design, construction and operation
of development on land subject to landslide hazard are
compatible with the nature of the hazard and appropriately
respond to the constraints imposed by the hazard.
42 Ex. 1, vol. 2, at p 394.
-- 27 of 38 --
28
(c) The potential for erosion and land slippage associated with
land use and development is minimised.
...”43
[43] Further, and in “8.2.10 Landslide hazard and steep land overlay code”44:
“…
8.2.10.2 Purpose and overall outcomes
(1) The purpose of the Landslide hazard and steep land overlay
code is to ensure:-
(a) development avoids or mitigates the potential adverse
impacts of landslide hazard on people, property,
economic activity and the environment; and
(b) development on steep land is avoided or otherwise
limited in scale and intensity, and is sensitively located
and designed to minimise adverse impacts on scenic
amenity, the environment and public safety.
(2) The overall outcomes sought for the Landslide hazard and
steep land overlay code are the following:-
(a) development in areas at risk from landslide hazard is
compatible with the nature of the hazard;
(b) the risk to people, property and the natural environment
from landslide hazard is minimised;
(c) development does not result in a material increase in
the extent or severity of landslide hazard; and
(d) development on steep land occurs only where the
scenic and environmental quality and integrity of the
landscape is maintained and safe and efficient access
can be provided.”
[44] Following that and in “8.2.10.3”, the following assessment criteria is provided in
Table 8.2.10.3.1 as the performance outcome in respect of “risk of harm to people
and property”, in respect of both “landslide hazard areas” and “steep land”:
43 Ex. 1, vol. 2, at p 396.
44 Steep land is identified as involving “slopes of 15% or greater” and “identified on the “Landslide
Hazard and Steep Land Overlay Maps in schedule 2” to the scheme. See Exhibit 1, p 457 for the
“Landslide Hazard and Steep Land Overlay Map (i) (Landslide)” , where the land is designated as in
the “Moderate Hazard Area” category, and also Exhibit 1, volume 2, p 458 for the “Landslide
Hazard and Steep Land Overlay Map (ii) (Steep Land)”, where the land is mostly designated in the
category of “Slope greater than 25%” and otherwise in the category of “slope 20-25%”.
-- 28 of 38 --
29
“PO1 Development does not increase the risk of harm to people and
property as a result of landslide by either:-
(a) avoiding development in a landslide hazard area; or
(b) undertaking development in a landslide hazard area
only where strictly in accordance with best practice
geotechnical principles.”
and:
“PO2 Development, including associated access, does not increase
the risk of harm to people and property by:-
(a) avoiding development on steep land; or
(b) undertaking development on steep land only where
strictly in accordance with best practice geotechnical
principles.”
[45] Specifically as far as the discouragement of additional lots on the land is concerned,
it is pointed out that the land has been deliberately excluded from the urban growth
area and zoned so to be in the category where there is specific restriction on the
creation of additional lots and that this occurred despite the submission made by the
appellants to contrary effect, in the process of the making of the 2014 scheme.45 It
can be noted that in “9.4.4 Reconfiguring a lot code” and apart from more generally
stated purposes and overall outcomes, one particular overall outcome stated in
9.4.4.2(2) is:
“(c) development provides for subdivisions that result in the
creation of safe and healthy communities by:-
…
(iv) avoiding or mitigating the risk to people and
property from natural hazards;
…”
[46] Otherwise and as far as the performance and acceptable outcomes stated in “9.4.4.3
Assessment criteria”, it suffices to note that “Table 9.4.4.3.2 Minimum lot size and
dimensions”, simply notes that in respect of the “Limited development (landscape
residential) zone”:
“No new lots to be created.”
45 See Exhibit 7.
-- 29 of 38 --
30
The nature and extent of relevant conflict
[47] As has been noted, the relevant decision rule to be applied, pursuant to s 326 of SPA,
is that unless there are sufficient grounds to nevertheless justify the decision, it must
not conflict with a relevant instrument, such as a planning scheme. Because s 495(2)
of SPA also applies, to require that the decision in this appeal must be based on the
laws and policies applying when the application was made, but allowing a discretion
to also “give weight to any new laws and policies the court considers appropriate”, it
is necessary, in the first instance, to ascertain the nature and extent of conflict with
the Maroochy Scheme 2000, being the existing planning scheme at the time when the
application was made. Further and in this case and as such conflict is to be found, it
then falls to the appellant to establish that there are sufficient grounds to justify
approval of the application, despite the conflict and in the context of any appropriate
weight that is to be given to the conflict also with the now existing 2014 scheme.
[48] It can be noted that as a planning scheme implemented under the Integrated Planning
Act 1997 and consistently with s 2.1.23 of that Act, the planning policy in respect of
steep and unstable land in the Maroochy Plan 2000 is not articulated so as to prohibit
development on such land. In particular, reconfiguration of such land46 is not
prohibited but and as has been noted above, there are clear implications and express
statements of an expectation and policy that, as is the case here, the development of
land, including the creation of lots with slopes exceeding 25%, is generally to be
considered inconsistent with the planning intent of the scheme.
[49] Further and given the emphasis upon the risk of landslide in specifically identified
areas and upon the preservation of the safety of persons and property, having regard
to such risk, it is clear that the scheme allows for a conclusion, at a broad level, of a
policy of avoidance of such risk, rather than merely minimising it. As has already
been noted, the appellants’ emphasis has been upon the risk minimisation measures
identified by the geotechnical experts, particularly as that may be seen as consistent
with the premises of the risk minimisation aspects of the more detailed requirements
of the scheme. However, those provisions are calculated to operate over a broad
spectrum of situations, including in respect of land with slopes of 25% or less but
where there remains a risk of landslide and must be seen in the broader context of
46 As one only of the types of development within the purview of SPA: see s 7.
-- 30 of 38 --
31
operating upon an assumption that the risks of the particular development to which
they are to be applied fall into a category where it is appropriate to seek to minimise,
rather than avoid the risks involved.
[50] Accordingly, the appellants’ alternative submission, that any conflict with the
Maroochy Plan 2000 that might be found is only minor, should not be accepted. The
conflict is, for the reasons given, plainly extensive and significant.
The application of the “Coty Principle”?
[51] In the written submissions made for the appellants47 and in dealing with the question
as to what weight should be given to the conflict with the 2014 Plan, particular
reference is made to a number of cases decided in this court and which make reference
to or consider the application of the so-called “Coty Principle”, which it is also
pointed out, was recognised as having application in Queensland.48 The reference is
to the following extract from the judgment of Hardy J49:
“It is important, in the public interest, that whilst the Respondent
Council’s local scheme is under consideration this court should, in the
exercise of its appellate jurisdiction under Cl. 35 of the County
Ordinance, avoid, as far as possible, giving a judgment or establishing
any principle which would render more difficult the ultimate decision
as to the form the scheme should take. It is also important, in the public
interest, that during that period this court should, in the exercise of the
jurisdiction referred to, arrive at its judgment, as far as possible, in
consonance with the town planning decisions which have been
embodied in the local scheme in the course of preparation.”50
[52] Two observations may be made as to why it is not necessary to dwell on or examine
the references to these cases, in any particular detail. First and foremost, the “Coty
Principle” or as Thomas J described the situation in Lewiac Pty Ltd v Gold Coast City
Council51the considerations upon which Hardy J was persuaded to act, related to the
attribution of weight to a local scheme that was under consideration, rather than
effected, by the time the matter was before the court. As Fitzgerald P observed in Yu
Feng Pty Ltd v Maroochy Shire Council52:
47 At [102]-[117].
48 Lewiac Pty Ltd v Gold Coast City Council (1996) 2 Qd R 266 at 270-1.
49 Coty (England) Pty Ltd v Sydney City Council (1957) 2 LGRA 117.
50 See the appellant’s written submissions at [104] and [107].
51 (1996) 2 Qd R 266 at p .
52 (1996) 92 LGERA 41.
-- 31 of 38 --
32
“Coty establishes no more than that, when determining whether to
approve or refuse a planning application, it is permissible, in
appropriate cases, to take account of any provisions affecting the site
which are included in a general planning scheme which is in the course
of preparation; the weight to be accorded to either consistency or
inconsistency between the draft planning scheme and the application
will depend on the circumstances, including the stage to which the
draft planning scheme has progressed, and usually will only be one of
the factors to be considered, although in a particular case it might be
decisive.”
It can be observed that unlike that position, the position here is concerned with the
attribution of appropriate weight to conflict with the 2014 Plan, as is expressly
allowed by s 495(2) of SPA and as may be appropriate to the circumstances under
consideration.
[53] Secondly, and in any event and in consequence of the findings made in respect of the
conflict with the 2000 Plan, there is no question of any conflict with the 2014 Scheme
being given any decisive or determinative weight53 and the appellant’s submissions
in relation to such considerations, proceed upon an assumption that there is no conflict
with the 2000 Plan and that the application meets the requirements of that earlier
Plan.54
Are there sufficient grounds to justify an approval of the development, despite
the conflict?
[54] In that context, it is next appropriate to consider whether there are sufficient grounds
established to justify an approval of the development, despite the conflict. The first
point to note in this regard is that it is in this context that it appears to be appropriate
to give weight to the conflict with the 2014 scheme. This is particularly because it
can be seen that this conflict may be regarded as even more marked or stark, than the
conflict with the Maroochy Plan 2000. The 2014 plan may be seen as a strengthened
reiteration of an adopted policy which was against allowing the development of land
with slopes exceeding 25% and particularly development by way of subdivision of
such land.
[55] The conflict with the latter but presently operative scheme is therefore relevant to and
may be given weight in assessment of the nature and extent of conflict with the 2000
53 Cf Lewiac Pty Ltd v Gold Coast City Council (1996) 2 Qd R 266 at 270.
54 See in particular, appellant’s written submissions at [116].
-- 32 of 38 --
33
scheme and more particularly in assessing whether there are nevertheless sufficient
grounds to justify approval of the application which is the subject of this appeal.
[56] As contended by the respondent, such an attribution of weight to the conflict with the
2014 scheme is not inappropriate having regard to the further considerations that:
(a) whilst that scheme has come into effect, substantially after the dates
of the lodgement of the development application (on 7 September
2011) and this appeal (on 7 August 2012), there has been an absence
of earlier pursuit of the appeal and ultimately it has been pursued after
the 2014 scheme has been effected, despite and so as to effectively
reject, the appellants’ submission for different treatment in that plan;55
and
(b) there is no suggestion that the common planning strategy in each plan
and as to which the approval which is sought would be in conflict, and
particularly in the avoidance of creation of additional lots within the
relevant precinct and in discouragement of development of land with
a slope of more than 25%, is not soundly based. The evidently
precautionary approach which is adopted in these plans, is, as
observed by Mr Brown (the town planning expert engaged by the
respondent), “not surprising, given the unfortunate history of failure
of slopes (including within subdivisional estates) which have taken
place in the Buderim locality with consequential adverse impacts upon
public assets and private property”.56
[57] Further and as observed by Mr Brown:57
“The provisions of both planning schemes which discourage further
development on land in the respective zone in which the land is
included, i.e. Hillslope Residential Precinct Class (Buderim Scarpe
Landscape Conservation Planning Area) in MP 2000, and Limited
Development (Landscape Residential) Zone in the 2014 scheme, have
been soundly based having regard to:
(a) available geological mapping within the town planning
documents; and
(b) the results of the site investigations reflected in the
geotechnical reports available to the Court, including the joint
55 See Ex. 7
56 See Ex. 1, vol. 1 at p 241: JTPER at 6.6.1 and cf: the observations of the appellants’ town planner,
Mr Schomburgk, to similar effect and as stated in his individual report: Exhibit 4, at p 5 para 26
57 In his individual report: Ex. 6, at p 8 para 20
-- 33 of 38 --
34
reports of the geotechnical experts, and the recommendations
contained therein.”
[58] An essential distinction between that approach and the approach of Mr Schonburgk,
the town planner engaged by the appellants, may be seen in Mr Schonburgk’s reliance
on the risk minimisation strategies identified by the geotechnical experts, as
potentially being directed at compliance with the planning scheme and, therefore, the
removal of any conflict with the scheme. So much is evident in the following
conclusion stated by Mr Schonburgk:
“If the court is not satisfied that the geotechnical issues are
satisfactorily resolved, or capable of resolution, my comments in the
JER that ‘many of the alleged conflicts would remain, and there would
not, in my opinion, be any grounds that would be sufficient to justify
this approval despite those conflicts’ stand as my opinion.”
[59] However, and as has been noted, and notwithstanding the necessary steps that have
been identified by the geotechnical experts, as reflected in the agreed conditions
necessary to reduce the risks to any subdivided lots in the proposed development, the
essential conflict with the overall intent of the planning scheme, is not removed by
any such minimisation of risk. Therefore the approach of Mr Brown, is the more
acceptable and particularly because of his recognition that the geotechnical evidence
and the identified conditions arising therefrom, particularly serve to underscore the
essential planning imperative of avoidance of such development of such steeply
sloped land, in this location.
[60] Further and as correctly pointed out by the respondent, the measures that were
identified by the geotechnical assessment and which would be necessary conditions
of any approval, were essentially directed at protection of and minimisation of the
risks of landslide in relation to the proposed building envelopes and the identified
risks of landslide to the enjoyment of the land, otherwise remained effectively
unabated. Also, there would remain the prospect of necessity of ongoing
maintenance, in the sense of a need to remove any consequences of any slippage in
the catch berms, so as to maintain the effectiveness of such a measure, after any such
event.
[61] Accordingly, sufficient grounds to nevertheless justify the decision, pursuant to s
326(1)(b) of SPA, may not be simply found in these risk minimization measures, as
they particularly serve to identify rather than remove, the conflict at issue. As has
-- 34 of 38 --
35
been noted earlier in these reasons,58 such grounds must be found in matters of public
interest, rather than the personal circumstances of the appellant.
[62] When pressed with that requirement, counsel for the appellant identified only the
consideration that the proposed conditions included a requirement that the public
utility, in the form of the Unity Water Pump station, would benefit by the inclusion
of a retaining wall, to protect it from the instability of the slope below.
[63] It can be noted that the protection of that pump station would be a public benefit,
particularly given the obvious importance of it, as part of the infrastructure supplying
water to the Buderim escarpment. However, in circumstances where there is no
evidence suggesting that the pump station is in any particular danger due to any
potential land slide on the slope below, as it exists. Accordingly and where the
proposed measure is otherwise a step to be taken as a protective measure, in the event
of the proposed redevelopment, including earthworks on that slope, if the proposed
development were allowed to proceed, it should be concluded that any such public
benefit does not provide sufficient grounds to justify such an approval, despite the
nature and extent of conflict with the planning scheme.
Conclusion
[64] Accordingly, this appeal will be dismissed and the decision of the respondent made
on 2 July 2012, confirmed. Therefore, it is unnecessary to determine the remaining
dispute between the appellants and the co-respondent. Further, it is undesirable to do
so, even in any indicative sense as to what the view of this court would have been,
had it been necessary to consider the question.
[65] This is particularly because:
(a) The only issue was as to the width of the easement over the land, for
the purposes of the water mains which traverses the land to the pump
station;
(b) This issue only related to the question of the imposition of a condition
upon, rather than any contended impediment of, the proposed
development;
58 See para [9], above
-- 35 of 38 --
36
(c) Although it was produced both late and outside the parameters of the
pre-trial directions as to the production of evidence, the co-
respondents applied for leave to read and file an affidavit,59 directed
towards some practical consideration in respect of its contention for a
10 metre wide easement and that application was adjourned, pending
the outcome of the issues joined between the appellants and the
respondents, particularly due to the circumstances where the
appellants had not had an appropriate opportunity to respond to that
material;60 and
(d) It is now neither necessary nor desirable that further cost or effort be
expended in that regard.
[66] However, the co-respondents did seek to pursue its contention as far as it was based
upon the statutory considerations and in that regard, it may be noted that:
(a) The existing easement in respect of the water mains is just over
5 metres in width and has existed for over 40 years;61
(b) At the time of the subject application being properly made, on
7 September 2011, the Maroochy Plan 2000, set out the desired
standards of service for the water supply, trunk infrastructure, by
specific reference to established codes and standards, including the
“Water Services Association of Australia Code for Water Supply”.62
However and by Table 5.4, the 2000 Plan made the Operational Works
Code applicable to the assessment63 and the Operational Works Code
adopted “Planning Scheme Policy 5 Operation Works”64 (“PSP5”), as
an acceptable measure and the PSP5, in turn, modified the then Water
Services Association of Australia Code for Water Supply, WSA03-
2002 V2.3 (3.1.2.1), to provide that:65
“In general, water mains are not to be constructed on private
property, however, in instances where this is unavoidable it
will be necessary to provide an easement of minimum
3.0 metres width registered for the benefit of the Council on
the title of the land. The main is to be constructed centrally
59 Further affidavit of N W Killip, sworn 12/11/14 – see T 2-63.40.
60 See T 2-68.5-11.
61 See co-respondent’s written submissions at [13] and Ex. 1, vol. 2, at p 661
62 Ex. 1, vol. 2 at pp 352 and 370.
63 Ex. 1, vol. 1 at p 75.
64 See Ex YYL10, to the Affidavit of Yee Yang Lim, filed by leave on 13/11/14, at Item A1.2.
65 See Ex YYL11 to the Affidavit of Yee Yang Lim, at p 30.
-- 36 of 38 --
37
within the easement. A wider easement may be necessary in
some instances, as determined by the Water Agency, to
ensure adequate access for maintenance purposes.”;
(c) Otherwise, the Water Services Association of Australia Code
for Water Supply Version 3.1 (WSA03-2002 V2.3) provided
in 4.3.3:66
“… specific requirements for the use of an easement shall be
obtained in writing from the water agency, and shall at least
include:
(a) the zone – of – influence of the trench for the water main.
(b) sufficient width and drainage capacity to minimise the
risk of consequential damage in the event of a main’s
failure.
(c) sufficient width for access for construction/maintenance.
(d) additional access to allow for future upsizing, if
appropriate.”
(d) From April 2011, the Water Services Association of Australia Code
for Supply WSA03-2011 V3.1, repeated (in 5.4.4) those specific
requirements and additionally provided for “default easement
guidelines” (in Table 5.2) and for a minimum 6.0 metre easement in
respect of temporary mains in private property, but in the context of a
guideline that no permanent mains are to be located within private
property;
(e) Further and as from 1 July 2013, WSA03-2011 V3.1 was modified to
become the “SEQ Design and Construction Code” (“ SEQ Code”) and
was gazetted pursuant to the South-East Queensland Water
(Distribution and Retail Restructuring) Act 2009, so as to become the
Uniform Code applicable to all development in South East
Queensland.67 The co-respondent notes that the current SEQ Code
modifies the 2011 Code and relevantly provides for amendments to
Table 5.2, to “amend the easement width to 6m for reticulation mains
(up to and including 300mm NB) and 10m for trunk mains” and to
insert at the end of the clause that “the developer shall arrange for the
provision of any easements over private property and registration of
such easements”.
[67] The co-respondent then notes the provisions of s 755D of SPA, as having the effect,
after the SEQ Code came into effect, of inserting the SEQ Code as one of the matters
66 See Ex YYL12 to the Affidavit of Yee Yang Lim, at p 74.
67 Ex. 1, vol. 2, at p 704.
-- 37 of 38 --
38
or things, against which assessment is to be made pursuant to s 314(2) of SPA and,
pursuant to s 755D(2)(b), having the effect of prevailing to the extent of any
inconsistency with a planning scheme. Although and in reference to those provisions,
a contention was noted as to the potential overriding of s 495(2)(a) of SPA, that was
not pressed and the co-respondent’s argument therefore depended upon the weight to
be applied to the SEQ Code pursuant to s 495(2)(a). However, it must be noted that
the particular reference to s 755D of SPA is to a provision which was omitted from
SPA pursuant to the Water Supply Services Legislation Amendment Act 2014,68 as
from 1 July 2014 and that situation remains presently unelaborated in submissions.
[68] Notwithstanding that it was an important part of the co-respondent’s contention that
the particular requirements of the planning scheme and adopted codes, was applicable
to a single pipeline, whereas it is common ground that there is a double pipeline
traversing the land, there is the difficulty that has been noted in relation to the
legislative provisions referred to as adopting the SEQ Code and in any event:
(a) The ultimate issue is as to whether an easement of 10 metre width, as
contended by the co-respondent, is (pursuant to s 345(1)(a) of SPA)
both “relevant to but not an unreasonable imposition on the
development or use of the premises as a consequence of the
development”; and
(b) As was noted in the written submissions for the co-respondent,69 a
conclusion on that issue would depend on how much weight is to be
given to the SEQ Code and it can be further noted, as was the
“appellant’s position” this may ultimately require consideration of the
material relating to the practical considerations or identified
requirements as to the easement, in order to assess the reasonableness
of the co-respondent’s contentions.
68 Although there is presently a s 755D in SPA, that is a different provision inserted by the State
Development, Infrastructure and Planning (Red Tape Reduction) and Other Legislation Amendment
Act 2014 No. 40, as from 1/10/14.
69 At [6].
-- 38 of 38 --
Official source: https://www.sclqld.org.au/caselaw/QPEC/2015/058