Gas Safety (Gas Installation) Regulations 1999
i
Gas Safety (Gas Installation) Regulations 1999
S.R. No. 6/1999
TABLE OF PROVISIONS
Regulation Page
PART 1—PRELIMINARY 1
1. Objectives 1
2. Authorising provisions 1
3. Commencement 2
4. Definitions 2
5. Matters excluded from the operation of the regulations 3
6. Application for exemption 3
7. Application of adopted standards 4
8. Type A gas installation 4
PART 2—APPLIANCES 6
9. Application for acceptance of new Type A appliance or class of
new Type A appliances 6
10. Application for acceptance of second-hand Type A appliance or
class of Type A appliances 6
11. Testing of appliances 6
12. Compliance plates for new Type A appliances 6
13. Compliance plates for second-hand Type A appliances 7
PART 3—GASFITTING WORK 8
Division 1—Standards 8
14. Prescribed standard for Type B appliances 8
15. Standards for second-hand Type A appliances 8
16. Prescribed standards for gas installations 8
Division 2—General requirements in relation to gasfitting work 8
17. Purpose of Division 8
18. Safety of installation 9
19. Clearance of consumer piping 9
20. Gas pressure raising devices in consumer piping 9
Division 3—Responsibilities of person carrying out gasfitting work 9
-- 1 of 35 --
Regulation Page
ii
21. Reporting of gas incidents 9
22. Dangerous gas installations 10
Division 4—Standards and requirements in relation to special
gasfitting work 10
23. Application 10
24. Notice of proposal to carry out special gasfitting work 10
25. Hot-tapping work 11
Division 5—Special requirements for high pressure consumer piping 11
26. Application 11
27. Standard for high pressure consumer piping 11
28. Approval of installation of high pressure consumer piping 11
PART 4—GAS INSTALLATIONS 13
29. Prescribed Type A gas installations 13
30. Application for acceptance of gas installation 13
31. Inspection and testing of gas installations 14
32. Compliance plates for Type B appliances in Type B gas
installations 14
33. Notice of LP Gas installations 15
34. Connection of gas to installation 15
PART 5—GENERAL 16
35. Duty to keep Type B appliance in a proper state of repair 16
36. Duty to report gas incidents 16
37. Power of inspector to disconnect or order disconnection 16
38. Exception for supply of gas by gas company 17
__________________
SCHEDULES 18
SCHEDULE 1—Standards and codes 18
SCHEDULE 2—Application for exemption 19
SCHEDULE 3—Information to be supplied by persons seeking
acceptance of a new Type A appliance 21
SCHEDULE 4—Information to be supplied by persons seeking
acceptance of a second-hand Type A appliance 23
SCHEDULE 5—Compliance plate details—new Type A appliance 24
SCHEDULE 6—Compliance plate details—second-hand Type A
appliance 25
-- 2 of 35 --
Regulation Page
iii
SCHEDULE 7—Information to be supplied by persons seeking
acceptance of a gas installation 26
SCHEDULE 8—Additional information to be supplied for a Type B
appliance in a Type B gas installation 27
SCHEDULE 9—Statement of compliance 29
SCHEDULE 10—Compliance plate details—Type B appliance 30
SCHEDULE 11—Information to be supplied in relation to Type A gas
installation to operate on LP gas 31
═══════════════
NOTES 32
-- 3 of 35 --
1
STATUTORY RULES 1999
S.R. No. 6/1999
Gas Safety Act 1997
Gas Safety (Gas Installation) Regulations 1999
The Governor in Council makes the following Regulations:
Dated: 19 January 1999
Responsible Minister:
ALAN STOCKDALE
Treasurer
STACEY ROBERTSON
Acting Clerk of the Executive Council
PART 1—PRELIMINARY
1. Objectives
The objectives of these Regulations are—
(a) to provide for standards for gasfitting work;
(b) to provide for the procedures relating to the
acceptance of appliances and gas
installations;
(c) to make provision generally in relation to the
safety of gasfitting work, gas installations
and appliances.
2. Authorising provisions
These Regulations are made under sections 69, 72,
73 and 118 of the Gas Safety Act 1997.
-- 4 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
2
3. Commencement
These Regulations come into operation on
1 February 1999.
4. Definitions
In these Regulations—
"Act" means the Gas Safety Act 1997;
"AG" immediately followed by a group of
numerals means the particular code
published by The Australian Gas Association
A.C.N. 004 206 044 and listed in Schedule
1;
"AS" immediately followed by a group of
numerals or a group of one or more letters
and one or more numerals means the
particular standard or code published by
Standards Australia and listed in Schedule 1;
"commercial butane" means a liquefied
petroleum gas which consists of more than
90% butanes and butylenes;
"commercial propane" means a liquefied
petroleum gas which consists of more than
90% propane and propylene;
"commissioning" does not include repair or
maintenance;
"consumer piping" has the same meaning as it
has in AG 601;
"hot-tapping work" means the connecting of a
branch to consumer piping whilst the pipe
contains gas under pressure;
"licensed person" means a person who is
licensed under Part 12A of the Building Act
1993 to perform gasfitting work;
r. 3
-- 5 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
3
"LP Gas" means commercial butane or
commercial propane which is intended for
use in an appliance but which is not intended
to be used for automotive purposes or as a
pressure pack propellant;
"operating pressure" has the same meaning as it
has in AG 601;
"pressure" has the same meaning as it has in
AG 601;
"rated working pressure" has the same meaning
as it has in AG 601;
"registered person" means a person who is
registered under Part 12A of the Building
Act 1993 to perform gasfitting work.
5. Matters excluded from the operation of the
regulations
These Regulations do not apply to—
(a) the construction, assembly or manufacture
of—
(i) a brick or masonry flue; or
(ii) a metal flue exceeding 450 millimetres
internal diameter; or
(iii) that part of a metal flue above a roof or
other surface where the part exceeds
10 metres in height above that roof or
other surface; or
(iv) a Type A appliance; or
(b) the use of gas for automotive purposes.
6. Application for exemption
An application to the Office under section 72(3)
of the Act must be in the form of Schedule 2.
r. 5
-- 6 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
4
7. Application of adopted standards
(1) The adoption by these Regulations of a standard
or code does not include a provision that—
(a) specifies or defines the respective rights,
responsibilities or obligations between
themselves of any employer, occupier, client,
manufacturer, designer, supplier or any other
person or body; or
(b) specifies the responsibilities of any
tradesperson or other building worker,
architect, engineer, authority or any other
person or body; or
(c) permits a departure from the standard, code
or specification at the sole discretion of any
employer, occupier, client, manufacturer,
designer, supplier or any other person or
body.
(2) A standard or code adopted by these Regulations
and listed in Schedule 1 is adopted as published
from time to time.
8. Type A gas installation
(1) The following classes of residential premises are
prescribed for the purpose of the definition of
"Type A gas installation" in the Act—
(a) Class 1a buildings, Class 2 buildings and
Class 4 buildings within the meaning of the
Building Regulations 1994 1 ; and
(b) caravans and mobile homes.
(2) The following classes of commercial premises are
prescribed for the purpose of the definition of
"Type A gas installation" in the Act—
(a) Class 5 buildings not exceeding 3 storeys;
and
r. 7
-- 7 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
5
(b) Class 6 buildings not exceeding 3 storeys—
within the meaning of the Building Regulations
1994.
(3) For the purposes of paragraph (b) of the definition
of "Type A gas installation" in the Act—
(a) the prescribed amount of gas consumption is
500 megajoules per hour; and
(b) the prescribed length is 50 metres.
_______________
r. 8
-- 8 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
6
PART 2—APPLIANCES
9. Application for acceptance of new Type A appliance
or class of new Type A appliances
An application under section 69 of the Act for
acceptance of a new Type A appliance or class of
new Type A appliances must contain or be
accompanied by the information listed in
Schedule 3.
10. Application for acceptance of second-hand Type A
appliance or class of Type A appliances
An application under section 69 of the Act for
acceptance of a second-hand Type A appliance or
class of second-hand Type A appliances must
contain or be accompanied by the information
listed in Schedule 4.
11. Testing of appliances
(1) Before a Type A appliance is accepted by the
Office under section 69 of the Act, the Office may
require the appliance to be tested to determine the
safety of the appliance for its intended use.
(2) If the Office is not satisfied with results of tests
carried out under this regulation, it may require
the applicant to arrange for further tests to be
carried out.
(3) All tests required under this regulation or under a
condition imposed under section 69(4) of the Act
must be carried out by a testing authority accepted
by the Office.
12. Compliance plates for new Type A appliances
If the Office requires a compliance plate to be
affixed to a new Type A appliance in accordance
with a condition of an acceptance under section 69
of the Act, the compliance plate—
r. 9
-- 9 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
7
(a) must be a compliance plate issued by the
Office; and
(b) must be securely affixed to the appliance—
(i) by a person approved by the Director;
and
(ii) in a place that is readily accessible by
any person inspecting the appliance;
and
(c) must be in the form of Schedule 5 and meet
the requirements of Schedule 5.
13. Compliance plates for second-hand Type A appliances
If the Office requires a compliance plate to be
affixed to a second-hand Type A appliance in
accordance with a condition of an acceptance
under section 69 of the Act, the compliance
plate—
(a) must be a compliance plate issued by the
Office; and
(b) must be securely affixed to the appliance—
(i) by a person approved by the Director;
and
(ii) in a place that is readily accessible by
any person inspecting the appliance;
and
(c) must be in the form of Schedule 6 and meet
the requirements of Schedule 6.
_______________
r. 13
-- 10 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
8
PART 3—GASFITTING WORK
Division 1—Standards
14. Prescribed standard for Type B appliances
For the purposes of section 72(2) of the Act the
prescribed standard in relation to Type B
appliances is AS 3814/ AG 501.
15. Standards for second-hand Type A appliances
(1) For the purposes of section 72(2) of the Act, the
Office may determine standards for Type A
second-hand appliances.
(2) The Office must take into account any relevant
standard or code listed in Schedule 1 in
determining that standard.
16. Prescribed standards for gas installations
(1) Subject to sub-regulation (2), for the purposes of
section 72(2) of the Act the prescribed standard in
relation to gas installations is AG 601.
(2) AG 601 applies under sub-regulation (1) as if the
special local requirements in Appendix L of
AG 601 in relation to common (combined) flues
applied to all gases.
Division 2—General requirements in relation to gasfitting
work
17. Purpose of Division
This Division prescribes requirements for the
purposes of section 72 of the Act.
r. 14
-- 11 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
9
18. Safety of installation
(1) A person carrying out gasfitting work on a gas
installation must ensure that the gas installation is
not made unsafe during the gasfitting work.
(2) A person carrying out gasfitting work on a gas
installation must ensure that the gas installation is
safe for use on the completion of the gasfitting
work.
19. Clearance of consumer piping
A person carrying out gasfitting work must ensure
that the consumer piping connected to a gas
company's meter assembly has a clearance of at
least 30 millimetres from the meter or any device,
component or pipe connected to the meter inlet.
20. Gas pressure raising devices in consumer piping
A person who installs a gas pressure raising
device in consumer piping must ensure that the
meter and gas installation are protected from over-
pressurisation, pulsation, reverse flow or vacuum.
Division 3—Responsibilities of person carrying out gasfitting
work
21. Reporting of gas incidents
(1) A person carrying out gasfitting work on a gas
installation must report to the Office and to the
gas company which supplies gas to the
installation, without delay, any gas incident which
occurs during the carrying out of that gasfitting
work.
Penalty: 20 penalty units.
(2) If a person carries out gasfitting work on a Type B
appliance and the person is aware that the work is
required because of a gas incident which had
occurred in relation to that appliance, the person
r. 18
-- 12 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
10
must, without delay after becoming so aware,
report the gas incident to the Office and to the gas
company which supplies gas to the gas installation
of which the appliance forms part.
Penalty: 20 penalty units.
22. Dangerous gas installations
(1) If a person carrying out gasfitting work on a gas
installation becomes aware of a danger arising
from a defect in the gas installation, the person
must immediately—
(a) take such steps as are necessary to make the
installation safe; and
(b) notify the owner of the gas installation and
the occupier of the premises in which the
installation is situated of the defect.
Penalty: 20 penalty units.
(2) If the person carrying out the gasfitting work is
unable to make the gas installation safe, he or she
must notify the gas company which supplies gas
to the installation of the defect.
Penalty: 20 penalty units.
Division 4—Standards and requirements in relation to
special gasfitting work
23. Application
This Division prescribes requirements for the
purposes of section 72 of the Act and applies
despite anything to the contrary in Division 1.
24. Notice of proposal to carry out special gasfitting work
A person proposing to carry out or who is
responsible for the carrying out of any of the
following classes of gasfitting work must give at
r. 22
-- 13 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
11
least 48 hours notice to the Office before carrying
out that work—
(a) welding of steel pipe;
(b) fusion jointing of polyethylene pipe;
(c) hot-tapping work.
25. Hot-tapping work
(1) A person must not carry out hot-tapping work
unless that work has been authorised by the
Office.
(2) Hot-tapping work must comply with the standards
determined by the Office for that work.
Division 5—Special requirements for high pressure
consumer piping
26. Application
This Division prescribes requirements for the
purposes of section 72 of the Act but does not
apply to consumer piping to which AG 601
applies.
27. Standard for high pressure consumer piping
Consumer piping which is to have an operating
pressure in excess of 200 kilopascals must comply
with the standards determined by the Office in
respect of that piping.
28. Approval of installation of high pressure consumer
piping
(1) A person must not install consumer piping which
is to have an operating pressure in excess of
200 kilopascals unless the Office has accepted a
proposal for the installation of the consumer
piping.
(2) An application for acceptance must—
r. 25
-- 14 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
12
(a) be made in writing; and
(b) contain or be accompanied by details of the
proposed design and construction of the
consumer piping.
_______________
r. 28
-- 15 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
13
PART 4—GAS INSTALLATIONS
29. Prescribed Type A gas installations
The following classes of Type A gas installation
are prescribed for the purposes of section 73 of
the Act—
(a) a gas installation for residential premises
within a Class 2 or Class 4 building (within
the meaning of the Building Regulations
1994) exceeding 3 storeys;
(b) a gas installation in a building with more
than one meter where the meters are located
in a common area.
30. Application for acceptance of gas installation
(1) An application under section 73 of the Act for
acceptance of a gas installation must contain or be
accompanied by the information listed in
Schedule 7.
(2) If a gas installation contains a Type B appliance,
an application under section 73 of the Act for
acceptance of the gas installation must also
contain or be accompanied by the information
listed in Schedule 8.
(3) In addition to the information required under sub-
regulation (1), the Office in order to determine the
safety of the gas installation may require the
applicant—
(a) to provide a copy of any design, analysis,
logic flow chart, program, calculation,
drawing or specification for the gas
installation;
(b) to provide a sample of a material, component
or other item to be used in the gas
installation;
r. 29
-- 16 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
14
(c) to remove and submit joints made in a pipe;
(d) to have a non-destructive test carried out on
a pipe and its joints.
(4) For the purposes of section 73(2)(c) of the Act a
statement of compliance—
(a) must be in the form of Schedule 9; and
(b) must be signed by—
(i) if the application relates to a Type B
appliance, a person who is licensed
under Part 12A of the Building Act
1993 to carry out specialised plumbing
work in respect of Type B appliances;
and
(ii) in any other case, a licensed person.
31. Inspection and testing of gas installations
(1) Before accepting a gas installation under section
73 of the Act, the Office may—
(a) inspect the gas installation; and
(b) require it to be tested to determine whether it
complies with the Act and these Regulations.
(2) For the purposes of carrying out any inspection or
test under sub-regulation (1), the Office may
remove any part of the gas installation from the
installation or the premises in which it is situated.
32. Compliance plates for Type B appliances in Type B
gas installations
If the Office requires a compliance plate to be
affixed to a Type B appliance in accordance with
a condition of an acceptance of a gas installation
under section 73 of the Act, the compliance
plate—
r. 31
-- 17 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
15
(a) must be a compliance plate issued by the
Office; and
(b) must be securely affixed to the Type B
appliance forming part of the gas
installation—
(i) by a person approved by the Director;
and
(ii) in a place that is readily accessible by
any person inspecting the appliance;
and
(c) must be in the form of Schedule 10 and meet
the requirements of Schedule 10.
33. Notice of LP Gas installations
If a licensed person carries out or supervises the
carrying out of gasfitting work on a Type A gas
installation which is to operate on LP Gas and the
gasfitting work is work for which a compliance
certificate would be required under section 221ZH
of the Building Act 1993, the licensed person
must within 5 days of the completion of that work
give the Office a notice specifying the information
set out in Schedule 11.
Penalty: 2 penalty units.
34. Connection of gas to installation
A person carrying out gasfitting work must not
connect gas to any part of a Type B gas
installation or to any part of a Type A gas
installation of a prescribed class unless that part of
the gas installation has been accepted by the
Office under section 73 of the Act.
Penalty: 20 penalty units.
_______________
r. 33
-- 18 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
16
PART 5—GENERAL
35. Duty to keep Type B appliance in a proper state of
repair
A person who is the owner of a Type B appliance
must keep that appliance in a proper state of
repair.
Penalty: 20 penalty units.
36. Duty to report gas incidents
If a gas incident occurs in relation to a Type B
appliance the owner of the appliance must report
the gas incident, without delay, to the Office and
to the gas company which supplies gas to the gas
installation of which the appliance forms part.
Penalty: 20 penalty units.
37. Power of inspector to disconnect or order
disconnection
(1) If an inspector determines from an inspection
under the Act or these Regulations that a gas
installation—
(a) does not comply with the Act or these
Regulations; or
(b) is defective or unsafe—
the inspector may—
(c) disconnect the gas installation or any part of
the gas installation from the gas supply; or
(d) order any person to disconnect the gas
installation or any part of the gas installation
from the gas supply.
r. 35
-- 19 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
17
(2) A person must comply with an order under sub-
regulation (1).
Penalty: 20 penalty units.
(3) A person must not connect gas to a gas
installation or any part of a gas installation which
has been disconnected by or on the order of an
inspector under this regulation, unless the Office
or an inspector has authorised the connection.
Penalty: 20 penalty units.
38. Exception for supply of gas by gas company
For the purposes of section 34(2) of the Act it is a
prescribed circumstance if the gas company
supplies gas for commissioning purposes with the
approval of the Office.
__________________
r. 38
-- 20 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
18
SCHEDULES
SCHEDULE 1
STANDARDS AND CODES
AG 601—Gas Installation Code (to the extent that it applies to gas in
Victoria).
AS 3814/AG 501—Code for industrial and commercial gas-fired appliances.
_______________
Sch. 1
-- 21 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
19
SCHEDULE 2
Gas Safety Act 1997
Gas Safety (Gas Installation) Regulations 1999
APPLICATION FOR EXEMPTION
(Section 72)
(Regulation 6)
To: Office of Gas Safety
Full name of applicant:
Address of applicant:
I apply under section 72(3) of the Act for an exemption from compliance
with the following standards and requirements:
in respect of work to be performed—
for (name of customer):
at (address of gas installation):
Name and address of person carrying out gasfitting work:
Details of proposed gasfitting work:
I apply for exemption from the specified standards and requirements in the
following respects: (Give a full statement of the nature of the exemption
sought)
Sch. 2
-- 22 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
20
The reasons why it is believed that compliance is not warranted, considering
both safety and cost, are:
(If space below is insufficient please attach a separate sheet.)
Dated:
Signature of applicant:
Full name of applicant:
_______________
Sch. 2
-- 23 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
21
SCHEDULE 3
INFORMATION TO BE SUPPLIED BY PERSONS SEEKING
ACCEPTANCE OF A NEW TYPE A APPLIANCE
(Section 69)
(Regulation 9)
1. Name and address of person applying for acceptance.
2. Details of test results received from a testing agency accepted by the
Office of Gas Safety:
3. Appliance details:
Details regarding the appliance, including where relevant:
(a) Manufacturer's name.
(b) Model identification.
(c) Maximum and minimum gas consumption (MJ/h).
(d) Nominal gas consumption.
(e) Gas type/s.
(f) Maximum and minimum gas supply pressures.
(g) Gas pressure at burner head for the maximum and minimum gas
consumption.
(h) Gas pressure at burner head for the nominal gas consumption.
(i) Burner ignition details (pilots, etc.).
(j) Flueing details.
(k) Installation instructions.
4. Component details:
Details regarding components, including where relevant:
(a) Manufacturer's name.
(b) Model identification.
(c) Gas type/s.
(d) Maximum and minimum gas supply pressures.
(e) Rated working pressure.
Sch. 3
-- 24 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
22
(f) Maximum and minimum gas flow rates.
(g) Electrical specifications, ratings, etc.
5. Valve train schematic diagram:
A schematic diagram clearly indicating:
(a) All components (including brand and model).
(b) Rated working pressure of all components.
(c) Proposed settings of all adjustable devices.
6. Appliance electrical circuit diagram:
A circuit diagram in ladder-logic format clearly indicating:
(a) Safety and control circuits.
(b) Details of all major components (including brand and model).
(c) Method of operation of all major components.
_______________
Sch. 3
-- 25 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
23
SCHEDULE 4
INFORMATION TO BE SUPPLIED BY PERSONS SEEKING
ACCEPTANCE OF A SECOND-HAND TYPE A APPLIANCE
(Section 69)
(Regulation 10)
1. Name and address of person applying for acceptance.
2. Appliance type.
3. Description of appliance for which approval is sought.
4. Details identifying the appliance, including model number.
5. Date of application.
6. AGA certification number of appliance.
7. Location at which appliance may be inspected.
_______________
Sch. 4
-- 26 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
24
SCHEDULE 5
(Section 69)
(Regulation 12)
COMPLIANCE PLATE DETAILS
NEW TYPE A APPLIANCE
State of Victoria
Office of Gas Safety
COMPLIANCE PLATE
NEW TYPE A APPLIANCE
This appliance has been accepted under section 69 of the
Gas Safety Act 1997.
OGS Acceptance No.:
Date:
_______________
Sch. 5
-- 27 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
25
SCHEDULE 6
(Section 69)
(Regulation 13)
COMPLIANCE PLATE DETAILS
SECOND-HAND TYPE A APPLIANCE
State of Victoria
Office of Gas Safety
COMPLIANCE PLATE
SECOND-HAND
TYPE A APPLIANCE
This appliance has been inspected and complies with
current safety requirements.
Inspected by:
OGS Authorisation No.:
Date:
_______________
Sch. 6
-- 28 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
26
SCHEDULE 7
INFORMATION TO BE SUPPLIED BY PERSONS SEEKING
ACCEPTANCE OF A GAS INSTALLATION
(Section 73)
(Regulation 30)
1. Details of person commissioning the gas installation—
Full Name:
Address:
Phone number:
Plumbing Industry Board Registration No.:
2. Address of gas installation.
3. Consumer's name and site contact name.
4. Type of work.
5. Type of gas.
6. Summary of work.
7. Commencement and completion dates for work.
_______________
Sch. 7
-- 29 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
27
SCHEDULE 8
ADDITIONAL INFORMATION TO BE SUPPLIED FOR A
TYPE B APPLIANCE IN A TYPE B GAS INSTALLATION
(Section 73)
(Regulation 30)
1. Appliance details:
Details regarding the appliance, including where relevant:
(a) Manufacturer's name.
(b) Model identification.
(c) Nominal gas consumption (MJ/h).
(d) Gas type.
(e) Maximum and minimum gas supply pressures.
(f) Purge times.
(g) Gas pressure at burner head for the nominal gas consumption.
(h) Combustion chamber volume.
(i) Purge volume, being the total volume swept from the entry of the
purge medium to the point of emission including interconnecting
ductwork.
(j) Serial number.
(k) Date of manufacture.
2. Valve train schematic diagram.
A schematic diagram clearly indicating:
(a) All components (including brand and model).
(b) Rated working pressure of all components.
(c) Proposed settings of all adjustable devices.
3. Electrical circuit diagram.
A circuit diagram in ladder-logic format clearly indicating:
(a) Safety and control circuits.
(b) Details of all major components (including brand and model).
(c) Method of operation of all major components.
Sch. 8
-- 30 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
28
4. Purge time calculation.
Calculation of the time required to purge the appliance in accordance
with AS 3814/AG 501.
5. Safe start gas rate.
Where required by AS 3814/AG 501 calculation of the safe start gas
rate or the critical time for ignition or critical energy.
6. Explosion relief area and dilution air flow rate (where relevant).
If the appliance process involves solvents or dusts and where required
by AS 3814/AG 501, provide details of, and calculations for, explosion
relief area and dilution air flow rates.
7. Details of flueing.
8. Details of ventilation.
_______________
Sch. 8
-- 31 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
29
SCHEDULE 9
STATEMENT OF COMPLIANCE
(Section 73)
(Regulation 30)
Certification by licensed person
I certify that this gas installation meets the requirements of the Gas Safety
Act 1997 and that the required tests have been carried out and it will be safe
for gas to be made available to the consumer.
Signature:
Date:
_______________
Sch. 9
-- 32 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
30
SCHEDULE 10
(Section 73)
(Regulation 32)
COMPLIANCE PLATE DETAILS
TYPE B APPLIANCE
State of Victoria
Office of Gas Safety
COMPLIANCE PLATE
TYPE B APPLIANCE
This appliance has been commissioned in compliance with
the Gas Safety Act 1997.
OGS Acceptance No.:
Appliance Serial No.:
Installed at:
Date:
_______________
Sch. 10
-- 33 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
31
SCHEDULE 11
(Regulation 33)
INFORMATION TO BE SUPPLIED IN RELATION TO TYPE
A GAS INSTALLATION TO OPERATE ON LP GAS
1. Details of licensed person—
Full name:
Address:
Phone number:
Plumbing Industry Board Registration No.
2. Certificate of Compliance No.
3. Address of gas installation.
4. Consumer's name and site contact name.
5. Type of work.
6. Summary of work.
7. Commencement and completion dates for work.
═══════════════
Sch. 11
-- 34 of 35 --
S.R. No. 6/1999
Gas Safety (Gas Installation) Regulations 1999
32
NOTES
1 Reg. 8(1)(a): S.R. No. 81/1994. Reprint No. 4 as at 14 May 1998.
——
The following table of applied, adopted or incorporated matter is included in
accordance with the requirements of regulation 6 of the Subordinate
Legislation Regulations 1994.
Table of Applied, Adopted or Incorporated Matter
Statutory Rule
Provision
Title of applied, adopted or
incorporated document
Matter in
applied,
adopted or
incorporated
document
Reg. 14,
Schedules 1, 8
AS 3814/ AG 501—Code for
industrial and commercial
gas-fired appliances
The whole
Regs 16, 26,
Schedule 1
AG 601—Gas Installation
Code
The whole (to
the extent that it
applies to
Victoria)
Notes
-- 35 of 35 --